24
 
 
 
 
E2-1P2/1P5/101/2P2/2P5/201- - N4X(IP65)TYPE INSTALLATION : 
SWITCH
POWER
Potentiometer
REV-0-FWD
SWITCH
L1 L2
RUN
STOP
3 Phases
IM
ENT
DSP
FUN
DATA
RESET
100~120V
or       
200-240V
50/60 Hz 
Single Phases
T3T2T1
 
 
 
 
CIRCUIT DIAGRAM 
 
 
   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
NOTE: 
(1). Input source : single-phase(L1,L2, 
ensurin
 
that it is connected to a 100~120 or 200~240 
supply. 
(2). Output Moter : three-phase(
,T1,T2,T3). 
Caution : 
‧Do not start or stop the inverter using the 
main circuit power. 
‧FOR E2-1P2~201- -N4S TYPE : 
Please always remain REV-0-FWD switch at 0 
position.    In order to keep inverter has no 
running signal before power-on again after 
power supply interrupted.Otherwise, injury may
result. 
‧FOR E2-1P2~201- -N4S TYPE : 
Please always remain RE or FW switch at OFF 
position.    In order to keep inverter has no 
running signal before power-on again after 
power supply interrupted.Otherwise, injury may
result. 
 
3 
PHASE 
IM 
10V 
VI 
0V
 
FW 
RE 
12V
 
L1 
 
L2 
T1 
T2 
T3
 
POWER 
SWITCH
 
REV-0-FWD 
SWITCH
 
Potentiometer 
AC 
100~120 
or 
200~240 
50/60HZ
 
NOTE : 
1. POWER SWITCH , REV-0-FWD SWITCH AND 
    Potentiometer are only for E2-1P2~201- N4S TYPE 
2. Power supply cable : #14 AGE (2.0mm² ) 
3. Motor cable : #16 AGE (1.25mm² ) 
4. Torque value of Screw : 
   (1). Power/Motor cable (plug in) Therminal : 5kg-cm(4.34 in-lb
   (2). Remote control wire : 4kg-cm(3.47 in-lb) 
   (3). Outer Cover (M4) : 6kg-cm(5.20 in-lb) 
123.4 mm
198.9 mm