TECO T-verter N2 Series - Frequency Limits (Fn_06, Fn_07); Target Speed Detection (Fn_08, Fn_09)

TECO T-verter N2 Series
83 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
34
Fn_05 B C Fn_05 B C Fn_05 B C
0/9 6.5% 6.5% 3/12 9.5% 4.9% 6/15 10.0% 5.1%
1/10 7.5% 6.1% 4/13 20.0% 6.1% 7/16 12.0% 4.7%
215~230
415~430
2/11 8.5% 5.5% 5/14 25.0% 5.8% 8/17 14.0% 4.2%
Fn_06 Upper Frequency Limit
You can adjust the maximum speed of the motor by raising the Upper Frequency limit at (Fn_06)
Fn_07 Lower Frequency Limit
You can set the minimum speed for the motor by adjusting the Lower frequency Limit at (Fn_07)
100%
Internal
Frequency
Signal
0%
Fn_08 At Target Speed 0 ~ 400 Hz
You can close a Multi-function output at terminal at a determined target speed at terminals
(10 & 11), You must assign (Fn_61) to ( 2~4 ) along with determining your target speed at Fn_08
Fn_09 Target Speed Detection 0 ~ 30 Hz
When the Fn_61 set to 2, the terminals 10 & 11 status will follow the output frequency
Hz
times
off on off
Note:
Terminals 10 & 11 are normally open during power off, and normally closed during power on.
Fn_06 (Upper Frequency Limit)
Fn_07 (Lower Frequency Limit)
Fn08
Fn09
Fn09