33
Fn_05 = 0 - 17 V/F Curves
Fn_05 50Hz Fn_05 60Hz
General
Purpose
0
V
100%
B
C Hz
0.1 2.5 50 400
9
V
100%
B
C Hz
0.1 3 60 400
High
Starting
Torque
1
2
3
V
100%
Hz
0.1 2.5 50 400
10
11
12
V
100%
Hz
0.1 3 60 400
Variable
Torque
Operation
4
5
V
100%
Hz
0.1 25 50 400
13
14
V
100%
Hz
0.1 30 60 400
Constant
HP
Operation
6
7
8
V
100%
B
C Hz
0.1 5 50 400
15
16
17
V
100%
B
C Hz
0.1 6 60 400
Fn_05 B C Fn_05 B C Fn_05 B C
0/9 7.5% 7.5% 3/12 20.0% 7.5% 6/15 15.0% 7.5%
1/10 10.0% 7.5% 4/13 17.5% 7.5% 7/16 20.0% 7.5%
2P5~203
401~405
2/11 15.0% 7.5% 5/14 25.0% 7.5% 8/17 25.0% 7.5%
0/9 7.5% 7.5% 3/12 12.0% 7.5% 6/15 10.4% 7.5%
1/10 9.0% 7.5% 4/13 17.5% 7.5% 7/16 13.0% 7.5%
205~210
408~410
2/11 10.5% 7.5% 5/14 25.0% 7.5% 8/17 15.4% 7.5%