TECshow BEAMER - Troubleshooting Guide; Problem and Remedy Table; Reference Information

TECshow BEAMER
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Problem Probable cause(s) Remedy
No response from xture
when power is applies
No power to xture Check power cables
Primary fuse blown Replace fuse
Secondary fuse blown Replace fuse
Fixture resets but does
not respond correctly
to controller(DMX mode
operation)
Controller not connected Connect controller
Incorrect addressing of the xtures Check address setting on xture and controller
Bad data link connection
Inspect cables and correct poor connections
and/or broken cables.
Conict between tracking and vector control Eliminate scene cross-fade on controller
Data link not terminated Insert termination plug in output of last xture
Defective xture or 2 devices transmitting on link
Bypass xtures one at a time until normal oper-
ation is regained: unplug both connectors and
connect them directly together
Colors cannot be mixed Random color mixing is on Turn o random color mixing
Fixture does not reset
correctly
Electronic or mechanical failure Contact service technician
No light, lamp cuts out
intermittently, or burns
out too quickly
Lamp missing or blown Disconnect xture and replace lamp
Fixture or lamp is too hot
Allow xture to cool. If problem persists, contact
service technician
Troubleshooting
Reference
Control menu
DMX Channel
Specication
BEAMER