Temperature
comp. range
0.... 60°C
Temperature
effect
• Zero point
• Measuring range
± 0,15 % /10 K
± 0,15 % /10 K
Degree of pro-
tection
• permissible rel.
humidity
IP 65 to EN 60529/IEC 529
< 90%, non-condensing
Emitted inter-
ference
2)
acc. to EN 61326
Noise immunity
2)
acc. to EN 61326
Temperature
ranges
• Storage
• Mat. measured
• Environment
-20 .... 70 °C
-30 .... 85 °C (-30 … 100°C for measuring range
100 bar)
-10 .... 60 °C
Housing Stainless steel, Optional black protective cap
Weight Approx. 0.4 kg
2)
Conformity declaration on request
8. CE – conformity
The manometer complies with all requirements of EN 61 326 with
regard to interference emission and immunity for use in industrial
areas. Installation must be carried out correctly in order to maintain
the effective protection from electromagnetic interference.