11
A special care is required when performing the tilting window
cleaning operation due to its weight.
Window cleaning operation that require the windshield to be ope-
ned should be performed by two service staff (one person holds
the tilted glass, the other person cleans internal glass surfaces, see
(Fig. 6).
Fig. 6
Lines attached to the glass are not security, but only
determine the degree of opening the windshield.
Do not spray water or detergent on electrical components and equipment.
1.
Do not use sharp tools to remove dirt from the external and internal surfaces of the device.
2.
The electrical installation does not require any maintenance
3.
Do not use sharp tools to remove dirt from the external and internal surfaces of the device.
4.
The refrigeration system does not require any maintenance except for periodic cleaning
of the condenser.
The condenser is serviced from the front or back of the device depending on the model.
Checking the purity of the condenser should be done:
at least once a month,
if necessary, e.g. in case of obstructed compressor start, abnormal noise or hot air exhausted
underneath the unit or considerable reduction of cooling effectiveness.
If the unit condenser is contaminated / dirty, and at least once a month, clean it. To do this:
disconnect the device from the power supply
remove perforated plate or grille covering the refrigerating unit (Fig. 7)
clean the filter mat (figure 8) mechanically with a brush or by a vacuum cleaner, removing dust,
packaging waste, etc.;
Mount again perforated plate or grille covering the refrigerating unit.
IN THE CASE OF CONTAMINATION OF THE UNIT CONDENSER,
THE RIBS, REMOVING DUST, POWDER, REMAINS OF PACKAGE, ETC.
THE MANUFACTURER DOESN’T TAKES ANY RESPONSIBILITY.

Related product manuals