The compressor of the device is adapted to work at a mains voltage not lower than 220 V
and not higher than 240 V.
Operating the device outside of these power supply parameters can lead to irreparable
damage to the compressor.
2.3.
Installation and use:
1.
When installing refrigerated device, remember that they give off a lot of heat. If the store room is
not sufficiently ventilated, this leads in a short time to excessive increase in the room temperature
and, as a consequence, to too high temperature and condensation pressure and a decrease in
the efficiency of the entire device. The compressor then works under overload conditions and in
extreme cases it can lead to permanent damage to the refrigerant unit. For these reasons, it is
recommended to:
–
Ensure good ventilation of the store room.
– Do not install the device in a place exposed to direct exposure of sunlight.
–
Be sure to keep the openings ventilation holes devices, free from closures
or obstacles.
– Periodic (frequent) checking of condenser unit condition
–
Setting the refrigeration unit away from heat sources (e.g. radiators, etc.)
and in a place not exposed to sunlight
–
Do not setting the furniture in the immediate operating range of the fans
(e.g ceiling fans, air conditioner fans).
It is forbidden to set or install the device near external ignition sources.
2.
Accurate leveling of the device contributes to the reduction of the noise level of the unit, allows
correct positioning of the glass and guarantees complete removing condensate from the drip trays.
It is forbidden to set the device in sloping position it may make it difficult to drain condensate
and lead to failure.