Alarm functions
„E0” – temperature sensor failure.
„E1” – defrost sensor failure.
If the word
OFF
appears, press and hold the button
for about 3 seconds.
In the event of an alarm, report to the nearest service center.
2.6.
Operating the thermostat – Dixell
Fig. 5
Change of the temperature setting
1.
Press the button SET for 2 seconds: the temperature value will appear on the screen, the LED °C
or °F will start flashing.
2.
Increase or decrease the temperature using the and buttons to achieve the new value.
3.
Press again
SET
button or wait 5 seconds to confirm the new temperature value.
Additional defrosting
The device works in automatic defrosting mode at 4–6 hours intervals. If you notice incomplete
defrosting, perform manual defrost, press and hold the button for about minimum 2 seconds.
Operating diodes and thermostat messages
Compressor operation LED
– turns on when the compressor is running.
Defrost LED– turns on when the device is in the process of defrosting.
Fan LED – turns on when the fan is working.
Alarm functions
„P1” – temperature sensor failure.
„P2” – defrost sensor failure.
In the event of an alarm, report to the nearest service center.