Note: REFRIGERANT R290
Be sure to keep the opening clear ventilation system free from closures or
obstacles.
It is forbidden to set up or install the device near external ignition sources.
Pay special attention to the minimum capacity (volume) (cubic capacity)
of the room in which the device will be installed. Minimum 1m
3
for every 8g
refrigerant R290 (amount of refrigerant given on the nameplate).
Repairs in the refrigeration system may only be performed by trained
technical personnel authorized to work with flammable agents (R290).
In devices it is necessary to pay special attention when working that they are located on flat and level
ground. It is unacceptable to set the devices in an inclined position - on uneven surface this may make it
difficult to drain condensate and lead to failure.
The compressor of the device is adapted to work at a mains voltage not lower than 220 V and not higher than
240 V.
Operating the device outside of these power supply parameters can lead to irreparable damage to the unit.
In the case of contamination of the unit condenser, and at least once a month, it should be cleaned with a soft
brush along the ribs, removing dust, powder, remains of package, etc.
For damage of compressor caused by contaminated/polluted condenser, the manufacturer doesn’t take any
responsibility.
If the non-detachable power cord is damaged, it should be replaced by the manufacturer or by a specialist
repair facility or by a qualified person in order to avoid a hazard
Do not cover the ventilation holes of the condenser refrigeration unit.
Do not use any mechanical or electrical means during defrosting.
Protect the refrigeration circuit against damage
For proper operation of the device and low energy consumption, the doors should be closed.
Do not setting the device in a place exposed to direct sunlight.