Dust at the dust
collecting tank.
There is too much dust in the dust
collection container.
Empty the dust collecting tank.
The toggle closures are not closed.
Close the toggle closers.
The seal of the dust collecting tank is
damaged.
The seal must be replaced.
The compressed air for the dedusting
is set too high.
Reduce the compressed air.
Dust at the service door
of the filter housing.
The door is not correctly closed.
Close the door.
The seal between the service door and
filter housing is damaged.
The seal must be replaced.
The compressed air for the dedusting
is set too high.
Reduce the compressed air.
Escape of dust at the hinge.
The hinge must be reoriented or
replaced.
Suction power too low
(smoke hardly
extracted).
Filter element is saturated.
Replace the filter package,
dispose of old filter properly!
Filter elements are saturated because
no compressed air is connected.
Connect compressed air.
Damage at the extraction elements.
Replace the extraction elements.
The motor rotates in the wrong
direction.
The rotating field of mains
connection point must be
changed.
Suction line contracted.
Check and fix.
Exhaust line contracted.
Check and fix.
Maybe throttle valves are used in the
suction line.
Adjust throttle valves.
The system is very noisy.
The motor rotates in the wrong
direction.
The rotating field of mains
connection point must be
changed.
There is no silencer mounted.
Mount the silencer.
The suction line or exhaust line are not
mounted.
Mount the line.
The unit is untight.
Check and fix.