11. Technical data
Version
2,2 - 4,0 kW
5,5 - 11,0 kW
Supply voltage
V
400
Frequency
Hz
50
Type of current
Ph
3 Ph + N + PE
engine power
kW
2,2
3,0
4,0
5,5
7,5
11,0
Air flow volume max.
m³/h
3500
4000
5000
6000
7500
10000
Negative pressure max.
Pa
2900
3300
3600
4100
3950
4600
Protection class
IP54
ISO class
F
Filter surface
31,2 / 40 / 50
62,4 / 80 / 100
Extraction performance
%
>99
Welding fume extraction class
(according to EN ISO 21904-1 / -2)
W3
Width
Depth
Height
mm
mm
mm
800
800
2370 (FilterCube 4N)
3030 (FilterCube 4H)
800
800
3030
Weight
kg
ca. 520 (FilterCube 4N)
ca. 580 (FilterCube 4H)
ca. 600
Sound pressure level
dB(A)
78
Allowed ambient temperature
°C
+5 to +35 (during operations)
-10 to +40 (during transport and storage)
Max. temperature of polluted air
at the capture point
°C
+50
Allowed max. humidity
%
70
Compressed air supply
dry / oil-free
Necessary external pressure
bar
see chapter “Connecting the compressed air supply”
BA_FilterCube_4_IFA_20230808_EN
31
08.08.2023

Table of Contents