EasyManuals Logo

Tektronix 2213 Service Manual

Tektronix 2213
224 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
ι
ι
ι
ι
ι
T
he
following
d
escri
p
tions
are
i
n
tende
d
to
familiarize
t
h
e
o
p
erator
with
t
h
e
location,
operation, and
f
un
ction
of
t
he
i
n str
u
ment's
con
trols,
connectors,
a
n
d
in
d
icato
r
s
.
R
efer
to
F
igure
2-3
for
location
of items
1 t
h
roug
h 7
.
I
n
ter
n
al
Graticule-
E
liminates
p
arallax
viewing
error
b
etween
t
h
e
trace
a
n
d
graticule
lines
.
R
ise-time
am
p
lit
ude
and
measurement
p
oints
are
i
nd
icated
at
t
h
e
left
e
dge of
t
h
e
graticule
.
P
O
WER
Switc
h
-Turns
instrume
n
t
p
ower
on
and
off
.
P
ress
in
for
ON
;
press
again
for
O
FF
.
A
UTO
F
OCU
S
Control-A
d
j
usts
dis
p
lay
for
optimum
d
efinition
.
Once
set,
t
he
foc
u
s
of
t
h
e
crt
dis
p
lay
will
MENEM
MENEM
MENEM
Ι
MENEM
MOMME
ONE
Ιι
2213
6 ο
ΡΜΑ
3397-04
F
ig
ur
e
2-3
.
P
owe
r
,
d
isplay, a
nd p
ro
b
e
ad
j
ust
co
n
t
r
ols,
conn
ecto
r
,
an
d
in
d
icator
.
REVN
O
V
1981
CO
N
T
R
O
L
S,
CO
NNE
CTO
R
S,
A
N
D
I
N
DICATO
R
S
P
OWER,
DISPLAY,
A
ND
PR
O
BE
AD
JUST
O
p
e
r
ati
n
g
Inst
r
uction
s-2213
Service
be
m
aintained as
ch
anges
occur
in t
h
e
intensity
level
of
t
he
trace
.
PR
O
BE
AD
JUST
Connecto
r
-
Pr
ovides
an
a
pp
roxi-
mately
0
.5
V, negative-going,
sq
ua
r
e-wave
voltage
(at
app
roximately
1
kH
z) t
hat
permits
t
h
e op
erator
to
compe
n
sate
voltage
pro
b
es
and
to ch
ec
k
operation
of
t
he
oscillosco
p
e
vertical
system
.
It
is
not
i
n
tende
d
to
ve
r
ify
t
h
e
accuracy
of
t
h
e
vertical
gain or
time-base
calibration
.
BEAM
F
I
ND
Switc
h
-Wh
en h
el
d
in,
compresses
t
h
e
dis
p
lay
to
wit
h
in
th
e
graticule
area
an
d
p
rovides
α
visible
viewing
intensity
to
ai
d
in
locating
off-scree
n
d
is
p
lays
.
TR
AC
E
R
OTATIO
N
Co
n
trol-Screw
d
river
co
n
trol
u
se
d to
align
t
he
crt
trace
wit
h
t
h
e
h
orizontal
graticule
lines
.
A
U
TO
I
NT
EN
SITY
Control-Ad
ju
sts
brig
h
tness
of
t h e
crt
d
is
p
lay
.
T
h
is
cont
r
ol
h
as
no
effect
w
h
e
n
t
h
e
BEAM
F
I
ND
switc
h
is
p
r
essed
in
.
Once
t
he
co
n
trol
is
set,
intensity
is
automatically
maintained
at
approximately
t
he
same
level
b
etwee
n
S
E
C/DI
V
switc
h
settings
from
0
.5
ms
per
d
ivision
to
0
.05
μ
s
per d
ivision
.
VER
TICA
L
R
efer
to
F
igu
r
e 2-4
for
location
of
items
8
t
h rough
16
.
S
ER
IA L and
M
od
Slots-T
h
e
S
ER
IA
L
slot
is
im-
printed
wit
h
t
he instrument's
serial
nu
mbe
r
.
T
h e
M
od
slot
co
n
tains
t
h
e
op
tio
n
num
b
er
t
h
at
h
as
b
een
installe
d
in t h e
instrume
n t
.
C
H
1
O
R
Χ
an
d C
H
2
O
R
Υ
Connectors-
P
rovide
for
a
p
plication
of
exter
n
al
signals
to
the
in
p
uts
of
t
h
e
vertical
d
eflection
system
or
for
an
Χ
-
Υ
dis
p
lay
.
In
t
he
Χ
-
Υ
mo
d
e, t
h
e
signal
connecte
d to
t
h
e
CH
1
O
R
Χ
connector
provi
d
es
h
orizo
n tal
d
eflection,
an
d
t
he
signal
con
n
ected to
t
he
CH
2
O
R
Υ
con-
nector
provid
es
vertical
d
eflection
.
GND
Connector-
P
rovi
d
es
direct
conn
ection to
instrument
c
h
assis
ground
.
2-3

Other manuals for Tektronix 2213

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix 2213 and is the answer not in the manual?

Tektronix 2213 Specifications

General IconGeneral
BrandTektronix
Model2213
CategoryTest Equipment
LanguageEnglish

Related product manuals