O
p
erating
I
n
str
u
ctions-2213
Service
d
is
p
lay
size
.
Ce
n
ter
t
he
com
p
resse
d
display
with
in
t
h
e
graticule
area
using
t
h
e
V
ertical
and H
orizontal
P
OSITIO
N
controls,
t
h
en
release
t
h
e
BEAM
F
I
ND
push b
utton
.
4
.
Ad
j
ust
t
he
TRIGG
ER
LEVEL
control,
if
necessary,
to
o
b
tain
α
sta
b
le
display
.
5
.
Set
t
h
e
ap
p
rop
riate
VO
L
TS/DI
V
switch
(es)
and
rea
d
ju
st
t h e
V
ertical
and
H
orizontal
P
OSITIO
N
controls
to
center
t
h
e
d
is
p
lay
wit
h
in t
h
e
gratic
u
le
area
.
6
.
Set
t
he S E
C/DI
V
switc
h
for
t
he
desire
d
number
of
cycles
of
t h e
d
is
p
layed
signal
.
T
h
en
a
dj
ust
the
A
U
TO
F
OC
US
control
for
t h
e
best-define
d
dis
p
lay
.
M
AG
N
I
F
I
E
D-S
WEEP
DIS
P
LAY
1
.
Obtain
α
Signal
Display
(see
preceding
instructions)
.
2
.
A
d
ju
st
t
h
e H
orizontal
P
OSITION
control to
move
t
h
e
trace
area
t
h
at
is
to
be
magnifie
d
to
t
he center of the
crt
graticule
(0 .5
d
ivision
on
each
si
d
e
of
t h e
center
vertical
graticule
line)
.
C
hange
t
h
e
S
E
C/DI
V
switc
h
setting
as
re
q
uired
.
3
.
Pull
out
t
he
S
E
C/DI
VV
ariable
kno
b
(
Χ
10) to
obtain
swee
p
magnification
.
4
.
Ad
j
ust
t
he
H
orizontal
P
OSITIO
N
control
for
p
recise
p
ositioni
ng of
t
h
e
magnifie
d
d
is
p
lay
.
5
.
To
calculate
t
he
magnified
sweep
s
pee
d
,
d
ivi
de
t
h
e
S
E
C/DI
V
switch
setting
by
10
.
D
E
LA
Y
E
D-S
WEEP
DIS
PL
AY
1
.
O
b
tain
α
Signal
Display
.
2
.
Select
I
NT
E
N
S
H
O
R
IZON
TA
L
M
OD
E
an
d
set
t
he
D
EL
AY
TIME
Range
Selector switc
h
to
t
h
e
d
esire
d
amount
of d
elay
time
.
3
.
Ad
j
ust
t
he
A
U
TO
I
NT
EN
SITY
control
as
nee
ded to
ma
k
e
t
he
intensifie
d
zone
d
istinguis
h
able
from
t
h
e
remain
d
er
of
t h
e
d
isplay
.
4
.
A
d
j
ust
t
h
e
D
EL
AY
TIME
MUL
TI
PL
I
ER
control to
move
t
h
e
start
of
t
h
e
inte
n
sified
zoneto
t
he
start
of
t
he
p
oint
of
interest
on
t
h
e
crt
trace
.
To
capture
an
event
t
h
at
occurs
after
t
he
swee
p
en
d
s,
a
dj
ust
t h e
start
of
t h e
intensifie
d
zone
p
ast
t
h
e
end of
t
he
swee
p
.
1 .
O
b
tain
α
baseline
trace
.
Χ
-
Υ
DIS
PL
AY
2
.
U
se
e
q
ual-le
n
gt
h
coaxial
cables,
or
t
h
e
two
10
Χ
probes
s
upp
lie
d
wit
h
t
he
i
n
strument,
to
apply
t
he h
ori-
zo
n
tal
signal
(X-axis)
to
t
he
CH
1
ORΧ
i
n
p
u
t
con
n
ector
and to
apply
t
h
e
vertical signal
(Y-axis)
to
t
he
CH
2
O
R
Υ
in
p
u
t
connector
.
3
.
Select
Χ
-
Υ
mode
b
y
switc
h
ing
t
h
e
S
E
C/DI
V
switc
h
to
its
fully
countercloc
k
wise
p
ositio
n
.
4
.
Advance
t
he
A
U
TO
I
N
T
EN
SITY
control
setting
until
two
d
ots are
dis
p
laye
d
.
T
he d
isplay
can
be p
ositione
d
h
orizontally
wit
h
t
h
e
H
orizon
tal
P
OSITIO
N
control
an
d
ve
r
tically
with
t
h
e
C
hannel 2 P
OSITIO
N
control
.
ΝΟΤΕ
T
he d
isplay
obtained
w
hen
sinusoidal
signals
are
applied
to the
Χ
-
and
Y-axis
is
called α
L
issajous
figure
.
This
display
is
commonly
used
to
compare
the
frequency
and
phase
relationships
of
two
input
signals
.
The
fre
q
uency
relationship
of
the
two
input
signals
d
etermines
the
pattern
seen
.
The
pattern
will
be
stable
only
if
α
common
divisor
exists
between
t
he
two
frequencies
.

Other manuals for Tektronix 2213

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix 2213 and is the answer not in the manual?

Tektronix 2213 Specifications

General IconGeneral
BrandTektronix
Model2213
CategoryTest Equipment
LanguageEnglish

Related product manuals