EasyManua.ls Logo

Tektronix 2221 - Page 138

Tektronix 2221
172 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix
A
-
2221
Operators
U
d
.
CHECK
-
The
bottom
and
top
of
the
trace
may
be
positioned
above
and
below
the
center
horizontal
graticule
line
by
rotating
the
Channel
2
POSITION
control
fully
clockwise
and
counterclockwise
respectively
.
k
.
Position
the
trace
0.5
division
above
the
bottom
hor
izontal
graticule
line
using
the
Channel
2
POSITION
control
,
1.
CHECK
-
Trace
shift
of
0.5
division
or
less
.
e
.
Move
the
cable
from
the
CH
2
OR
Y
input
connector
to
the
CH
1
OR
X
input
connector
.
Set
the
VERTICAL
MODE
switch
to
CH
1
.
m
.
Set
the
VERTICAL
MODE
switch
to
CH
1
.
u
f
.
Repeat
parts
c
and
d
using
the
Channel
1
controls
.
n
.
Repeat
steps
g
through
I
for
Channel
1
trace
.
u
g
.
Disconnect
the
test
equipment
from
the
instrument
.
6.
Check
Non
Store
Aberrations
ui
5.
Check
Acquisition
Position
Registration
a
.
Set
:
a
.
Set
:
10
mV
GND
VOLTS
/
DIV
(
both
)
AC
-
GND
-
DC
(
both
)
SEC
/
DIV
SAVE
/
CONT
BW
LIMIT
VOLTS
/
DIV
(
both
)
AC
-
GND
-
DC
(
both
)
SEC
/
DIV
STORE
/
NON
-
STORE
Off
(
button
out
)
2
mV
DC
0.05
us
NON
-
STORE
(
button
out
)
10
us
CONT
b
.
Position
the
trace
exactly
on
the
center
horizontal
graticule
line
using
the
Channel
1
POSITION
control
,
b
.
Connect
the
fast
-
rise
,
positive
-
going
square
-
wave
output
via
a
50
2
cable
,
a
10X
attenuator
,
and
a
50
12
ter
mination
to
the
CH
1
OR
X
input
connector
.
u
C.
Set
STORE
/
NON
-
STORE
switch
to
STORE
(
button
in
)
.
باب
C.
Set
the
generator
to
produce
a
1
MHz
,
5
-
division
display
.
d
.
CHECK
Trace
remains
within
0.5
division
of
the
center
graticule
line
.
u
d
.
CHECK
-
Display
aberrations
are
within
4
%
(
0.2
division
or
less
)
for
the
following
VOLTS
/
DIV
switch
set
tings
:
5
mV
through
50
mv
.
Adjust
the
generator
output
and
attach
or
remove
the
10X
attenuator
as
necessary
to
maintain
a
5
-
division
display
at
each
VOLTS
/
DIV
switch
setting
.
e
.
Set
:
VERTICAL
MODE
STORE
/
NON
-
STORE
CH
2
NON
-
STORE
u
f
.
Repeat
parts
b
through
d
for
Channel
2
trace
.
e
.
CHECK
-
Display
aberrations
are
within
6
%
(
0.25
division
or
less
)
for
the
following
VOLTS
/
DIV
switch
set
tings
:
0.1
V
through
0.5
V.
Adjust
the
generator
output
and
attach
or
remove
the
10X
attenuator
as
necessary
to
maintain
a
5
-
division
display
at
each
VOLTS
/
DIV
switch
setting
.
g
.
Position
the
trace
0.5
division
below
the
top
horizon
tal
graticule
line
using
the
Channel
2
POSITION
control
.
n
.
Set
SAVE
/
CONT
switch
to
SAVE
.
f
.
Disconnect
the
cable
from
the
CH
1
OR
X
input
con
nector
.
Reconnect
the
10x
attenuator
(
if
previously
removed
)
and
reduce
the
generator
amplitude
to
minimum
.
U
i
.
CHECK
-
Trace
shift
of
0.5
division
or
less
.
g
.
Connect
the
cable
to
the
CH
2
OR
Y
input
connec
tor
and
set
the
VERTICAL
MODE
switch
to
CH
2
.
j
.
Set
SAVE
/
CONT
switch
to
CONT
.
A
-
6

Related product manuals