EasyManua.ls Logo

Tektronix 2205 Service Manual

Tektronix 2205
210 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
I f O M / ; r T 7 i
ESC 3234 95 01
service Manual
Tektronix
2205
Oscilloscope
070-6716-00

Table of Contents

Other manuals for Tektronix 2205

Question and Answer IconNeed help?

Do you have a question about the Tektronix 2205 and is the answer not in the manual?

Tektronix 2205 Specifications

General IconGeneral
TypeOscilloscope
Bandwidth20 MHz
Channels2
Vertical Sensitivity5 mV/div to 5 V/div
Time Base0.2 μs/div to 0.5 s/div
Input Impedance1 MΩ, 20 pF
Maximum Input Voltage400 V (DC + AC peak)
Trigger ModesAuto, Normal
Power Supply100-240 VAC, 48-440 Hz

Summary

Operators Safety Summary

Grounding the Product

Ensures safe operation by connecting the power cord to a properly wired receptacle.

Power Cord and Fuse Safety

Guidelines for using the correct power cord and fuse to prevent hazards.

Servicing Safety Summary

Do Not Service Alone

Emphasizes the need for another person capable of rendering first aid during servicing.

Service Safety with Power On

Highlights the danger of touching exposed connections while the instrument is powered on.

Specification

Operating Information

Preparation for Use

Provides essential safety information and steps for initial start-up of the instrument.

Safety Guidelines

Crucial safety considerations for connecting the instrument and general warnings.

Line Voltage and Fuse Selection

Instructions on setting the voltage selector and installing the correct line fuse for operation.

Controls, Connectors, and Indicators

Describes the function and location of the instrument's front-panel controls, connectors, and indicators.

Theory of Operation

General Description

Provides a functional overview of the 2205 Oscilloscope, referring to block diagrams.

Detailed Circuit Descriptions

Provides in-depth explanations of specific circuits like Vertical, Trigger, Sweep, Horizontal, Z-Axis, Power Supply.

Performance Check Procedure

Introduction and Purpose

Explains the goal of verifying instrument performance and identifying calibration needs.

Adjustment Procedure

Maintenance

Corrective Maintenance

Describes component replacement, special parts, ordering, and maintenance aids.

Voltage/Waveform Setup Conditions

Power Supply Isolation Procedure

Details how to isolate loads from power supplies to locate short circuits.