Appendix
A
-
2221
Operators
HORIZONTAL
П
П
П
n
C
Equipment
Required
(
see
Table
A
-
1
)
:
Calibration
Generator
(
Item
1
)
Leveled
Sine
-
Wave
Generator
(
Item
2
)
Time
-
Mark
Generator
(
Item
3
)
50
22
BNC
Cable
(
Item
8
)
50
1
BNC
Termination
(
Item
12
)
INITIAL
CONTROL
SETTINGS
b
.
Select
50
ns
time
markers
from
the
time
-
marker
generator
Vertical
П
П
П
П
C.
Use
the
Channel
1
POSITION
control
to
center
the
display
vertically
.
Adjust
the
TRIGGER
LEVEL
control
for
a
stable
,
triggered
display
.
Channel
1
POSITION
VERTICAL
MODE
X
-
Y
BW
LIMIT
CH
1
VOLTS
/
DIV
CH
1
VOLTS
/
DIV
Variable
Channel
1
AC
-
GND
-
DC
Midrange
CH
1
Off
(
button
out
)
Off
(
button
out
)
0.5
V
CAL
detent
DC
d
.
Use
the
Horizontal
POSITION
control
to
align
the
2nd
time
marker
with
the
2nd
vertical
graticule
line
.
Horizontal
POSITION
SEC
/
DIV
SEC
/
DIV
Variable
X10
Magnifier
Midrange
0.05
us
CAL
detent
Off
(
knob
in
)
e
.
CHECK
-
Timing
accuracy
is
within
2
%
(
0.16
divi
sion
at
the
10th
vertical
graticule
line
)
and
linearity
is
within
5
%
(
0.1
division
over
any
two
of
the
center
eight
divisions
)
.
NOTE
Trigger
VAR
HOLDOFF
Mode
SLOPE
LEVEL
HF
REJECT
INT
SOURCE
EXT
COUPLING
NORM
P
-
P
AUTO
OUT
Midrange
OFF
VERT
MODE
INT
DC
-
10
For
checking
the
timing
accuracy
of
the
SEC
/
DIV
switch
settings
from
50
ms
to
0.5
s
,
watch
the
time
marker
tips
only
at
the
2nd
and
10th
vertical
grati
cule
lines
while
adjusting
the
Horizontal
POSITION
control
.
Storage
f
.
Repeat
parts
c
through
e
for
the
remaining
SEC
/
DIV
and
time
-
mark
generator
setting
combinations
shown
in
Table
A
-
5
under
the
"
Normal
(
X1
)
"
column
.
п
1
П
П
Л
п
П
П
STORE
/
NON
-
STORE
SAVE
/
CONT
TRIG
POS
NON
-
STORE
(
button
out
)
CONT
POSTTRIGGER
(
power
-
up
default
)
OFF
(
power
-
up
default
)
ON
(
power
-
up
default
)
g
.
Set
:
DISPLAY
ON
/
OFF
VECTORS
ON
/
OFF
0.05
us
SEC
/
DIV
X10
Magnifier
On
(
knob
out
)
PROCEDURE
STEPS
h
.
Select
10
ns
time
markers
from
the
time
-
mark
generator
1.
Check
Timing
Accuracy
and
Linearity
a
.
Connect
the
time
-
mark
generator
output
via
a
50
cable
and
a
50
2
termination
to
the
CH
1
OR
X
input
connector
.
i
.
Use
the
Horizontal
POSITION
control
to
align
the
1st
time
marker
that
is
25
ns
beyond
the
start
of
the
sweep
with
the
2nd
vertical
graticule
line
.
A
-
11
Л