EasyManuals Logo
Home>Tektronix>Test Equipment>2221

Tektronix 2221 User Manual

Tektronix 2221
172 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #33 background imageLoading...
Page #33 background image
Section
3-2221
Operators
Л
П
П
o
CONTROLS
,
CONNECTORS
,
AND
INDICATORS
Л
Л
Л
The
following
descriptions
are
intended
to
familiarize
the
operator
with
the
location
and
function
of
the
instrument's
controls
,
connectors
,
and
indicators
.
7
)
TRACE
ROTATION
Control
-
Permits
alignment
of
the
trace
with
the
horizontal
graticule
line
.
This
con
trol
is
a
screwdriver
adjustment
that
,
once
set
,
should
require
little
attention
during
normal
operation
.
POWER
AND
DISPLAY
8
INTENSITY
Control
-
Adjusts
the
brightness
of
all
displayed
NON
-
STORE
waveforms
.
See
Figure
3-1
for
the
location
of
items
1
through
9
.
9
Л
STORE
/
READOUT
INTENSITY
Control
-
Adjusts
the
brightness
of
the
STORE
mode
displayed
waveforms
and
the
readout
intensity
in
both
STORE
and
NON
-
STORE
modes
.
The
fully
counterclockwise
position
of
the
control
toggles
the
STORE
/
NON
STORE
readout
on
and
off
.
1
Internal
Graticule
-
Eliminates
parallax
viewing
error
between
the
trace
and
the
graticule
lines
.
Rise
-
time
amplitude
and
measurement
points
are
indicated
at
the
left
edge
of
the
graticule
.
C
VERTICAL
2
POWER
Switch
-
Turns
instrument
power
on
or
off
.
Press
in
for
ON
;
press
again
for
OFF
.
See
Figure
3-2
for
the
location
of
items
10
through
17
.
3
Power
On
Indicator
Lights
up
while
instrument
is
operating
.
4
11
П
П
FOCUS
Control
-
Adjusts
for
optimum
display
definition
.
Once
set
,
proper
focusing
is
maintained
over
a
wide
range
of
display
intensity
.
10
VOLTS
/
DIV
Switches
-
Select
the
vertical
channel
deflection
factors
from
2
mV
to
5
V
per
division
in
a
1-2-5
sequence
.
The
VOLTS
/
DIV
control
settings
for
displayed
waveforms
containing
cursor
symbols
are
shown
in
the
crt
readout
.
5
PROBE
ADJUST
Connector
-
Provides
an
approxi
mately
0.5
V
,
negative
-
going
,
square
-
wave
voltage
(
at
approximately
1
kHz
)
for
use
in
compensation
voltage
probes
and
checking
the
vertical
deflection
system
.
The
PROBE
ADJUST
output
is
not
intended
as
a
reference
in
checking
either
the
vertical
or
the
horizontal
accuracy
of
the
instrument
.
П
In
STORE
mode
,
SAVE
waveforms
and
waveforms
waiting
to
be
updated
between
trigger
events
may
be
vertically
expanded
or
compressed
by
up
to
a
factor
of
10
times
(
or
as
many
VOLTS
/
DIV
switch
positions
remaining
-
whichever
is
less
)
by
switching
the
corresponding
VOLTS
/
DIV
control
.
(
Waveforms
acquired
at
2
mV
/
div
cannot
be
expanded
and
waveforms
acquired
at
5
V
/
div
cannot
be
compressed
.
)
The
VOLTS
/
DIV
readout
reflects
the
vertical
scale
factor
of
the
displayed
waveform
.
If
the
VOLTS
/
DIV
switch
is
switched
beyond
the
available
expansion
or
compression
range
,
the
readout
is
tilted
to
indicate
that
the
VOLTS
/
DIV
switch
setting
and
the
VOLTS
/
DIV
readout
no
longer
agree
.
6
BEAM
FIND
Switch
-
Compresses
the
vertical
and
horizontal
deflection
to
within
the
graticule
area
and
intensifies
the
display
to
aid
the
user
in
locating
traces
that
are
overscanned
or
deflected
outside
of
the
crt
viewing
area
.
C
П
n
3-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix 2221 and is the answer not in the manual?

Tektronix 2221 Specifications