EasyManuals Logo

Tektronix 2221 User Manual

Tektronix 2221
172 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #73 background imageLoading...
Page #73 background image
O
Basic
Applications
-
2221
Operators
Substituting
these
values
into
the
formula
:
TIME
CHANGE
C
ATI
=
5.25
AV2-1
.
ZAY
Slope
1.74
V
5.42
S
0.32
V
/
S
100
90
VOLTAGE
CHANGE
LOW
-
LEVEL
SIGNAL
MEASUREMENTS
ACTIVE
CURSOR
AT
SECOND
POINT
OF
INTEREST
10
02
П
П
П
П
01.57
ils
CURSOR
AT
FIRST
POINT
OF
INTEREST
A
displayed
signal
acquired
in
STORE
mode
at
5
mV
per
division
may
be
vertically
expanded
up
to
ten
times
.
Figure
6-22
is
an
illustration
of
a
4
mV
peak
-
to
-
peak
signal
being
displayed
at
2
mV
per
division
.
The
stair
-
step
pat
tern
is
due
to
the
small
changes
of
signal
applied
to
the
digitizing
circuitry
when
STORE
mode
is
used
to
acquire
the
waveform
.
The
numerous
spikes
in
the
waveform
are
due
to
the
noise
accompanying
the
signal
.
4998-23
Figure
6-21
.
Slope
using
cursors
.
The
AVERAGE
Processing
mode
may
be
used
to
reduce
,
or
even
eliminate
,
the
noise
displayed
with
the
sig
.
nal
.
Even
though
the
signal
-
level
changes
applied
to
the
digitizing
circuitry
are
small
,
processing
of
the
average
waveform
data
results
in
a
smooth
display
of
the
signal
.
5.
Press
the
SAVE
/
CONT
switch
to
activate
SAVE
mode
to
save
the
acquired
waveform
and
to
provide
a
more
stable
display
for
measurement
.
6.
Use
the
CURSORS
control
to
move
the
active
cur
sor
to
the
first
point
of
interest
.
Figure
6-23
is
an
illustration
of
the
same
signal
level
as
displayed
in
Figure
6-22
,
but
the
waveform
was
averaged
before
being
displayed
.
Low
-
level
signals
can
be
acquired
in
the
same
manner
as
explained
in
previous
acquisition
procedures
.
External
triggering
may
be
helpful
for
produc
ing
a
stable
display
if
the
amplitude
of
the
signal
being
acquired
is
very
low
.
All
measurement
procedures
described
in
the
preceding
part
of
this
manual
are
also
valid
for
low
-
level
signals
.
7.
Push
the
SELECT
C1
/
C2
button
to
select
the
other
cursor
,
and
use
the
CURSORS
control
to
position
the
cur
sor
to
the
second
point
of
interest
.
O
8.
Read
the
voltage
difference
between
cursors
from
the
crt
readout
.
9.
Read
the
time
difference
between
the
two
mea
surement
points
from
the
crt
readout
.
100
i
90
10.
Slope
is
determined
by
using
the
measured
voltage
and
time
to
calculate
the
rate
of
change
using
the
follow
ing
formula
:
V
А
A
a
4mV
P
-
P
10
|
i
Slope
(
rate
of
change
)
Change
in
voltage
Change
in
time
2mV
!
4998-24
As
an
example
,
in
Figure
6-21
,
the
voltage
difference
between
the
measurement
points
is
1.74
V
,
and
the
time
difference
is
5.42
s
.
Figure
6-22
.
Low
-
level
signal
,
STORE
mode
.
O
6-21

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix 2221 and is the answer not in the manual?

Tektronix 2221 Specifications

General IconGeneral
BrandTektronix
Model2221
CategoryTest Equipment
LanguageEnglish

Related product manuals