Do you have a question about the Tektronix 2247A and is the answer not in the manual?
Type | Oscilloscope |
---|---|
Bandwidth | 100 MHz |
Channels | 4 |
Sample Rate | 1 GS/s |
Vertical Sensitivity | 2 mV/div to 5 V/div |
Maximum Input Voltage | 400 V (DC + AC peak) |
Input Impedance | 1 MΩ |
Trigger Modes | Auto, Normal, Single |
Trigger Sources | Channel 1, Channel 2, Line |
Display | CRT |
Power Requirements | 100-120 VAC |
Dimensions | 368 mm |
Provides an overview of the 2247A oscilloscope's features, capabilities, and system architecture.
Lists standard accessories provided with the 2247A oscilloscope instrument.
Covers essential safety, fuse replacement, and line voltage/power cord requirements.
Details the front panel controls for the CRT display, power switch, and intensity adjustments.
Describes vertical controls including position, mode selection, VOLTS/DIV settings, and coupling.
Explains horizontal controls like position, sweep speed, magnification, and mode selection.
Covers trigger system controls including A/B select, slope, holdoff, level, source, and coupling.
Explains the function of menu item select buttons, clear display, and measurement selection buttons.
Provides fundamental operating information and techniques for using the oscilloscope.
Covers proper grounding, probe usage, and coaxial cable considerations for reliable measurements.
Details the operation of measurement, service, and Store/Recall Setup menus.
Outlines the purpose and options available within the SERVICE MENU for diagnostics and calibration.
Describes the system for storing, recalling, and arranging front-panel setups.
Provides a procedure for setting up front-panel controls when the instrument is first turned on.
Explains how to automatically set up front-panel controls for a usable display of the applied signal.
Covers checking and adjusting probe compensation for accurate measurements.
Describes how to check the Channel 1 and Channel 2 vertical deflection system using the PROBE ADJUST signal.
Explains how to use time measurement cursors to check the horizontal deflection system.
Covers continuous measurements of DC, +PEAK, -PEAK, or PK-PK values of applied signals.
Provides a procedure for making a +peak voltage measurement using the oscilloscope.
Explains how to define a portion of a waveform for gated voltage measurements.
Provides a procedure for making time difference measurements using SEC cursors.
Details the procedure for setting a reference and measuring phase differences.
Explains how to use the built-in frequency counter/timer for accurate measurements.
Explains using tracking cursors for visual indication and numeric readout of trigger level.
Introduces electrical, environmental, and mechanical specifications for the 2247A.
Provides guidelines on how often to check instrument performance for accuracy.
Details electrical specifications for vertical and horizontal deflection systems, and trigger functions.
Explains the purpose of the Performance Check Procedure and its accessibility.
Lists all test equipment necessary for Performance Checks and Adjustments.
Details functional checks for Input Coupling, VOLTS/DIV trace shift, and deflection accuracy.
Outlines sensitivity checks for various trigger modes and frequencies.
Covers checks for sweep length, position range, and timing accuracy.
Details accuracy checks for SEC, VOLTS, and PHASE cursors.
Covers accuracy checks for DC Volts, Normal Mode Rejection Ratio, and Peak measurements.
Outlines procedures for checking Period, Width, and Rise Time Accuracy.
Details checks for external Z-axis input, probe adjustment, and auto setup functionality.
Introduces available instrument options and accessories.
Lists the standard accessories provided with each instrument.
Lists recommended optional accessories for the 2247A Oscilloscope.
Details how front-panel controls are set by the AUTO SETUP function.
Lists the default factory settings for various controls and selections.
Details the front-panel control settings for the "ADJUST FLAT TOP" factory setup.
Details the front-panel control settings for the "AUTO TO 100 MHz" factory setup.
Details the front-panel control settings for the "SELECTABLE TIME" factory setup.
Details the front-panel control settings for the "MANUAL A VOLTS" factory setup.
Details the front-panel control settings for the "SET CURSORS" factory setup.
Details the front-panel control settings for the "ADJUST CH 1 W/D" factory setup.
Details the front-panel control settings for the "SELECT DELAY" factory setup.
Details the front-panel control settings for the "MATCH EDGES" factory setup.