EasyManua.ls Logo

Tektronix 2221 - Page 81

Tektronix 2221
172 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Options
and
Accessories
-
2221
Operators
Table
7-3
O
Specific
Format
Choices
П
П
П
П
П
Option
10
GPIB
Side
Panel
The
Option
10
instrument
is
supplied
with
the
side
panels
shown
in
Figure
7.1
.
The
Option
10
side
panel
includes
one
AUXILIARY
connector
,
one
GPIB
(
IEEE
488
1978
)
interface
port
,
and
one
PARAMETERS
switch
.
The
Controls
,
Connectors
,
and
Indicators
part
of
this
manual
contains
information
on
the
use
of
the
AUXILIARY
Con
nector
.
Refer
to
Figure
7-1
for
location
of
the
Option
10
side
-
panel
controls
and
connectors
.
Format
Parameter
Choice
Made
Format
Characters
Not
transmitted
;
ignored
on
reception
,
Message
Terminator
Either
EOI
or
LF
can
be
selected
for
message
termination
.
Measurement
Terminator
Follows
program
message
unit
syntax
.
AUXILIARY
CONNECTOR
PARAMETERS
SWITCH
Link
Data
(
Arguments
)
Used
in
Listen
and
Talk
.
PARAMETERS
Multiple
Event
Reporting
AUXILIARY
CONNECTOR
REL
V
N.O.
RELAY
COMM
+
4.2
VOC
SIG
GND
2
ADOR
EDI
Not
implemented
to
report
all
events
on
a
single
query
.
Multiple
events
may
be
reported
by
using
multiple
queries
.
Descriptors
added
for
all
options
.
8
-
16
LF
OR
EDI
LON
TON
AUXI
AUX
2
EXT
CLK
RELAY
N.C.
X
П
Л
Л
SHIELD
GND
Instrument
Identification
Query
!
Set
Query
Extended
by
using
other
commands
.
CAUTION
$
25
Vpk
AND
<
100mA
ABS
,
MAX
APPLIED
TO
ANY
CONNECTOR
Device
Trigger
(
DT
)
Not
implemented
.
IEEE
STD
488
PORT
SHI
,
AHD
,
T5
,
L3
,
SR1
,
RL2
,
PPØ
.
DC1
,
DTO
,
CO
.
E2
INIT
Command
-000000000000
Causes
the
instrument
to
return
to
a
default
set
up
condition
.
Time
/
Date
Commands
Not
implemented
.
Stored
Setting
Commands
Not
implemented
.
GPIB
CONNECTOR
Waveform
Transmission
Implemented
.
6530-26
Return
to
Local
(
rt
!
)
Not
implemented
.
IEEE
728
Compliance
not
intended
.
Figure
7-1
.
Option
10
side
panel
.
Table
7-4
Implementation
of
Specific
Features
11
Л
Л
П
П
П
П
П
П
Feature
Choice
Made
Comments
Secondary
Addressing
Indicators
Not
implemented
.
ADDR
(
addressed
)
,
SRQ
(
service
request
)
,
and
PLOT
(
acquisitions
locked
out
)
indicators
are
included
.
A
ten
-
section
switch
sets
the
instrument's
bus
address
,
message
terminator
,
listen
-
only
or
talk
-
only
mode
,
and
makes
printer
/
plotter
selections
.
Parameter
Selection
Switch
settings
are
read
only
at
power
on
.
O
7-5

Related product manuals