20. Push the ↑ or ↓ arrow side-bezel button to position the cursor on the
Hostname field.
21. Push the Clear lower-bezel button.
22. Push the ↓ arrow side-bezel button to position the cursor on the Domain
Name field.
23. Push the Clear lower-bezel button.
24. Push the ↓ arrow side-bezel button to position the cursor on the Service
Name field.
25. Push the Clear lower-bezel button.
26. Push the OK Accept side-bezel button.
27. Push the Change e*Scope and LXI Password side-bezel button.
28. Push the Clear lower-bezel button.
29. Push the OK Accept side-bezel button.
The LAN system is disabled and no longer allows data traffic in or out. The
relevant LAN Ethernet settings are also cleared.
Enable the USB device port
Complete the following steps to enable the USB device.
1. Push the front panel Default Setup button.
2. Push the front-panel Utility button.
3. Push the Utility Page lower-bezel button and use the Multipurpose a knob
to select I/O.
4. Push the USB lower-bezel button.
5. Push the Connect to Computer or Connect to PictBridge Printer side-
bezel button to enable the USB device port.
Clear and sanitize procedures
MDO3000 Series Declassification and Security Instructions 9