EasyManua.ls Logo

Tektronix TDS 620A - Page 208

Tektronix TDS 620A
382 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Command Descriptions
2–190
TDS Family Oscilloscope Programmer Manual
MEASUrement :
REFLevel
?
MEASUrement:REFLevel:ABSolute:HIGH
Sets or queries the high reference level, and is the 100% reference level when
MEASUrement:REFLevel:METHod is set to ABSolute. This command is
equivalent to setting the Reference Levels in the Measure menu.
Measurement
MEASUrement:REFLevel:ABSolute:HIGH <NR3>
MEASUrement:REFLevel:ABSolute:HIGH?
HIGH
?
<Space> <NR3>
MEASUrement
:
REFLevel
:
ABSolute
:
<NR3> is the high reference level, in volts. The default is 0.0 V.
MEASUREMENT:REFLEVEL:ABSOLUTE:HIGH 1.71
sets the high reference level to 1.71 V.
MEASUrement:REFLevel:ABSolute:LOW
Sets or queries the low reference level, and is the 0% reference level when
MEASUrement:REFLevel:METHod is set to ABSolute. This command is
equivalent to setting the Reference Levels in the Measure menu.
Measurement
MEASUrement:REFLevel:ABSolute:LOW <NR3>
MEASUrement:REFLevel:ABSolute:LOW?