EasyManuals Logo

Tektronix TDS200 Series Programmer's Manual

Tektronix TDS200 Series
250 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #69 background imageLoading...
Page #69 background image
Command Descriptions
TDS200/1000/2000 Series Oscilloscope Programmer Manual
2−51
Vertical
CH<x>:BANdwidth { ON | OFF }
CH<x>:BANdwidth?
ON sets the channel bandwidth to 20 MHz.
OFF sets the channel bandwidth to the full bandwidth of the
oscilloscope.
In most acquisition modes, full bandwidth is 60 MHz, 100 MHz, or
200 MHz (depending on the oscilloscope model). There are
exceptions.
TDS1000 and TDS2000 Series
At vertical scales from 2.00 to 4.99 mV/div (sensitivity at the BNC;
that is, after the probe factor is removed), the full bandwidth is
20 MHz.
TDS200 Series
At vertical scales of 5 mV/div or less (sensitivity at the BNC; that is,
after the probe factor is removed), the full bandwidth is 20 MHz.
When the acquisition mode is Peak Detect, and the vertical scale at
the BNC is 10 mV/div or less, the full bandwidth is also 20 MHz.
CH2:BANDWIDth ON
sets the bandwidth of channel 2 to 20 MHz.
CH1:BANDWIDth?
might return OFF, which indicates that there is no bandwidth
limiting on channel 1.
Group
Syntax
Arguments
Examples

Table of Contents

Other manuals for Tektronix TDS200 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TDS200 Series and is the answer not in the manual?

Tektronix TDS200 Series Specifications

General IconGeneral
BrandTektronix
ModelTDS200 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals