Command Descriptions
TDS200/1000/2000 Series Oscilloscope Programmer Manual
2−53
Vertical
CH<x>:INVert { ON | OFF }
CH<x>:INVert?
ON inverts the specified oscilloscope channel.
OFF sets the specified oscilloscope channel to non-inverted.
CH1:INVert ON
inverts the signal on channel 1.
CH2:INVert?
might return OFF, indicating that channel 2 is not inverted.
CH<x>:POSition
Sets or queries the vertical position of the specified oscilloscope
channel. The position voltage value is applied to the signal before
digitization. This command is equivalent to adjusting the front-panel
VERTICAL POSITION knob.
Vertical
CH<x>:POSition <NR3>
CH<x>:POSition?
<NR3> is the position in divisions from the center graticule.
Table 2-23 lists the vertical position ranges using a 1X probe.
Group
Syntax
Arguments
Examples
Group
Syntax
Arguments