Command Descriptions
TDS200/1000/2000 Series Oscilloscope Programmer Manual
2−109
<NR3> specifies the point in the FFT waveform data record to display
at the center vertical graticule line. The data record point is a
percentage of the total record length, in the range of 0 to 100. The
default value is 50. How much data is displayed depends on the FFT
Zoom factor setting. The oscilloscope rounds <NR3> to the nearest
workable value.
MATH:FFT:HORizontal:POSition 25
sets the FFT waveform horizontal position such that the data at the
25% point of the record is centered on the display.
MATH:FFT:HORizontal:POSition?
might return 5.0E1, indicating that the 50% point in the data record
is horizontally centered on the display.
MATH:FFT:HORizontal:SCAle
NOTE. You can use this command with a TDS1000 or TDS2000
series, as well as a TDS200 series with a TDS2MM measurement
module.
Sets or queries the FFT math waveform horizontal zoom factor.
Horizontal
MATH:FFT:HORizontal:SCAle <NR3>
MATH:FFT:HORizontal:SCAle?
<NR3> specifies the horizontal magnification factor, where the axis of
magnification is the center vertical graticule line. Valid zoom factors
are 1, 2, 5, and 10. If other values are entered the oscilloscope
rounds the value of <NR3> to the nearest valid zoom factor.
Arguments
Examples
Group
Syntax
Arguments