Command Descriptions
2−1 12
TDS200/1000/2000 Series Oscilloscope Programmer Manual
MEASUrement?
Oscilloscope measurement parameters
MEASUrement?
might return the following:
:MEASUREMENT:MEAS1:TYPE PERIOD;UNITS s";SOURCE CH1;
:MEASUREMENT:MEAS2:TYPE FREQUENCY;UNITS Hz";SOURCE CH1;
:MEASUREMENT:MEAS3:TYPE PK2PK;UNITS V";SOURCE CH2;
:MEASUREMENT:MEAS4:TYPE MEAN;UNITS V";SOURCE CH2;
:MEASUREMENT:IMMED:TYPE CRMS;UNITS V";SOURCE CH1
MEASUrement:IMMed? (Query Only)
Returns all immediate measurement setup parameters. Immediate
queries and commands are the preferred methods for programming.
An immediate measurement selection is not visible or accessible
through the display screen or front panel.
Measurement
MEASUrement:IMMed?
Immediate measurement setup parameters
MEASUrement:IMMed?
might return PERIOD;s";CH1