Command Descriptions
2−80
TDS200/1000/2000 Series Oscilloscope Programmer Manual
DISplay:INVert { ON | OFF}
DISplay:INVert?
OFF chooses a default black-on-white display.
ON chooses a white-on-black display.
DISplay:PERSistence
Sets the length of time that data points are displayed.
Display
DISplay:PERSistence { 1 | 2 | 5 | INF | OFF }
DISplay:PERSistence?
1 | 2 | 5 specifies the length, in seconds, that the waveform points
are displayed on the screen.
INF specifies infinite persistence.
OFF specifies that persistence is turned off.
0 means that the persistence is turned off.
2 or 5 means that the persistence is set to two or five seconds.
99 means that the persistence is set to infinite.
DISplay:PERSistence 5
specifies that the waveform points are displayed on the screen for
five seconds before they fade.
Syntax
Arguments