Do you have a question about the Teledyne CombiFlash NextGen 100 and is the answer not in the manual?
Maximum Flow Rate | 100 mL/min |
---|---|
Flow Rate Range | 1-100 mL/min |
Detector Type | UV-Vis |
Number of Detectors | 1 |
Solvent Channels | 4 |
Fraction Collection | Yes |
Number of Channels | 4 |
Sample Capacity | up to 100 g |
Power Requirements | 100-240 VAC, 50/60 Hz |
Weight | Approx. 100 lbs |
Type | Automated Flash Chromatography System |
Column Size Compatibility | 4-100 g sample loading |
Illustrates and describes the various controls and features of the CombiFlash NextGen unit.
Provides essential safety information and general warnings for operating the CombiFlash NextGen system.
Provides instructions for carefully unpacking the CombiFlash NextGen system and inspecting contents.
Details the steps for connecting the CombiFlash NextGen system to the mains power supply.
Guides on making essential plumbing connections for the CombiFlash NextGen system.
Provides instructions for connecting and routing the drain lines for the CombiFlash NextGen system.
Details the procedure for powering on the CombiFlash NextGen system and initiating startup.
Guides on configuring the CombiFlash NextGen system for optimal performance and user needs.
Provides instructions for priming the solvent lines of the CombiFlash NextGen system before first use.
Recommends verifying system operation using the CombiFlash Universal verification kit.
Discusses methods for preparing samples, including liquid injection and solid sample cartridges.
Provides step-by-step instructions for loading a RediSep column into the CombiFlash NextGen.
Guides on how to start a separation run after system installation and sample preparation.
Details the Method Editor screen for controlling less common parameters not on the main screen.
Covers the operation, standby, and shutdown procedures for the PurIon Mass Detector.
Guides on creating efficient preparative gradient methods using flash columns.
Details the process of generating a focused gradient method based on a scouting run.
Guides on creating preparative gradient methods using analytical HPLC data.
Details how to calculate focused gradients from analytical HPLC data.
Outlines the minimum periodic maintenance requirements for safe and reliable operation.
Provides general instructions for cleaning the exterior surfaces of the CombiFlash NextGen system.
Details routine inspection tasks for the CombiFlash NextGen system components.
Provides procedures for cleaning the flow cell to maintain performance and lamp energy.
Details the quick cleaning procedure for the flow cell when recommended by a system alert.
Provides guidance on periodic cleaning of the ELSD spray chamber for maximum performance.
Covers maintenance procedures for the PurIon Mass Spectrometer, including component removal.
Guides on removing the ESI or APCI ion source housing from the PurIon system.
Details the procedure for replacing the ESI or APCI ion source housing on the PurIon.
Offers troubleshooting steps for common PurIon instrument issues and errors.