EasyManua.ls Logo

Teledyne CombiFlash Rf User Manual

Teledyne CombiFlash Rf
245 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
i
CombiFlash
®
Rf
+
User Manual
For indoor use only
COPYRIGHT © 2013 by
Teledyne Isco
4700 Superior St.
Lincoln, Nebraska, U.S.A. 68504
Phone: (402) 464-0231
Toll Free: (800) 228-4373
FAX: (402) 465-3022
Revision C, May 2015
Part #69-5233-650

Table of Contents

Questions and Answers:

Teledyne CombiFlash Rf Specifications

General IconGeneral
BrandTeledyne
ModelCombiFlash Rf
CategoryLaboratory Equipment
LanguageEnglish

Summary

Section 1 Introduction

1.1 Documentation Overview

Provides information on safety, unpacking, installation, certification, and warranty.

1.2 Product Overview

Describes the Teledyne Isco CombiFlash Rf chromatography system's features and applications.

CombiFlash System Configurations

Details various CombiFlash system configurations like Rf 150, Rf+, Lumen, PurIon, EZ Prep, and 4x.

1.4 Specifications

Lists physical, electrical, and performance specifications for Rf 150 and Rf+ systems.

1.5 Controls, Indicators, and Features of the CombiFlash Rf

Identifies front, side, and back panel controls and features of the CombiFlash Rf system.

1.6 Safety

Provides general warnings about hazardous practices, material classification, and ventilation.

1.7 For Additional Information

Provides contact information for technical assistance from Teledyne Isco.

Section 2 Preparation: Rf+, Rf+ Lumen, Rf+ PurIon, and EZ Prep Systems

2.1 Unpacking the Unit

Instructions for unpacking the CombiFlash Rf+, Rf+ Lumen, and optional 4x module.

2.3 Connect Power

Details connecting the system to mains power using the supplied IEC cord.

2.4 Connect Solvent Lines

Explains connecting solvent lines, including warnings about static discharge and tubing.

2.5 Connect Waste Lines

Explains connecting waste lines to diverter and inject valve outlets, with safety warnings.

2.6 EZ Prep Plumbing Connections

Covers pre-assembled EZ Prep plumbing, removing clamps, and placing lines in reservoirs.

2.8 Connect and Route Drain Lines

Guides testing and routing drain tubes for fraction collector and top shelf drains.

2.10 Install Collection Tube Racks

Lists available tube racks and instructions for loading tubes into racks.

2.12 Turn on Power

Details turning the system on, monitoring startup, and checking for operation readiness.

2.13 Configure the System

Guides system configuration via the PeakTrak menu, covering various settings.

2.13.1 Solvents

Explains managing solvents, adding names, and enabling solvent level sensing.

2.13.5 Vapor Limit

Explains the vapor sensor, limit settings, and troubleshooting alarms.

2.14 Prime the Solvent Lines

Guides priming solvent lines using the Auto Prime menu command.

2.15 System Verification

Recommends system verification using pre-packaged test kits.

Section 3 Preparation: Rf 150 Systems

3.1 Unpacking the Unit

Instructions for unpacking the CombiFlash Rf 150 system.

3.3 Connect Power

Details connecting the CombiFlash Rf 150 to mains power using the IEC power cord.

3.4 Connect Solvent Lines

Explains connecting solvent lines to the Rf 150 system's two solvent inlet ports.

3.5 Connect Waste Lines

Explains connecting waste lines to the Diverter Valve Waste port on the Rf 150 system.

3.9 Turn on Power

Details turning the Rf 150 system on, monitoring startup, and checking for operation readiness.

3.10 Configure the System

Guides Rf 150 system configuration via the PeakTrak menu.

3.10.1 Solvents

Explains managing solvents for the Rf 150 system, adding names.

3.10.4 Vapor Limit (Optional)

Explains the vapor sensor and limit settings for the Rf 150 system.

3.11 Prime the Solvent Lines

Guides priming solvent lines for the Rf 150 system using Auto Prime.

Section 4 Preparation: Optional 4x Module

4.1 Unpacking the Unit

Instructions for unpacking the CombiFlash Rf 4x module.

4.3 Connect Power

Details connecting the CombiFlash Rf 4x module to mains power.

4.4 Connect Solvent Lines

Explains connecting solvent lines to the Rf 4x module's ports.

4.5 Connect Waste Lines

Explains connecting waste lines to the six liquid waste ports on the Rf 4x module.

4.8 Remove Shipping Hardware

Guides removing shipping hardware from the injection valve assemblies.

4.10 Prime the Solvent Lines

Guides priming solvent lines for the Rf 4x module using Manual Control.

Section 5 Operation

5.1 Flash Sample Preparation

Discusses methods for sample preparation: liquid injection, solid cartridges, and pre-loading.

5.1.2 Solid Samples

Details preparing empty solid sample cartridges and mixing media with sample.

5.2 Loading a RediSep Rf Column

Provides instructions for loading a RediSep Rf column, including warnings and column selection.

5.3 Start a Default Method

Guides starting a run using default methods, including sample name and loading type selection.

5.4 During the Run

Allows system operation monitoring and gradient parameter modification during a run.

5.4.1 Run Control Buttons

Explains Play, Pause, and Stop buttons for controlling the run.

5.4.2 Bypassing the Solid Load Cartridge

Explains bypassing the solid load cartridge to relieve back pressure, with CAUTION.

5.5 EZ Prep Operation

Covers EZ Prep operation, including column mounting and sample preparation.

5.5.1 Column Mounting

Guides mounting HPLC columns and guard columns on the EZ Prep system.

5.5.2 Sample Preparation

Details HPLC sample preparation, injection loop volume, and solvent considerations.

5.5.3 Starting the Separation

Guides starting HPLC separations on the EZ Prep system, selecting columns and loading techniques.

Section 6 User Help Reference

6.1 PeakTrak Overview

Provides an overview of the PeakTrak control software and its interface.

6.1.2 Method File

Explains the role of Method files in controlling runs and their basic/advanced settings.

6.2 PeakTrak Menu Options

Lists PeakTrak menu options including File, Method Editor, MS, Tools, and Help.

6.2.2 Method Editor

Explains the Method Editor window, button bar, and sections.

6.2.3 MS

Details MS options for PurIon systems, including method development and manual control.

6.2.4 Tools

Lists tools options: Edit Defaults, Configuration, Set Admin Password, User Management.

6.3 PeakTrak Windows

Describes various PeakTrak windows like Main Window, Method Editor, and Gradient Optimizer.

6.3.2 Method Editor

Explains the Method Editor window layout and its various settings.

6.3.3 Gradient Optimizer

Guides generating gradients from TLC data using the Gradient Optimizer.

6.4.2 Editing a method

Allows tailoring system operation by editing basic and advanced method settings.

6.4.7 Bypassing the Solid Load Cartridge

Explains bypassing the solid load cartridge to relieve back pressure, with CAUTION.

Section 7 Remote Interfaces

7.1 Network Configuration

Guides configuring the system for corporate network use, including IP address settings.

7.1.1 Network PC Access

Lists PC recommendations for accessing a networked CombiFlash Rf system.

7.1.2 Network Printing

Explains configuring the system to print to a network printer.

7.2 Direct Connection

Details instructions for direct connection setup for Windows 7, Vista, XP, and 2000.

7.3 Direct Printing

Explains setting up a USB printer for direct printing from the CombiFlash Rf system.

Section 8 Maintenance

8.1 System Standby and Shut Down

Explains placing the system in Standby to conserve power and safe shutdown procedures.

8.2 Preventive Maintenance

Outlines preventive maintenance schedules: As Needed, Every Run, Monthly, Annually.

8.3 Cleaning

Guides cleaning exterior surfaces using detergent, water, and isopropyl alcohol.

8.4 Tubing Inspection

Guides monthly inspection of tubing, fittings, and drains for damage or leaks.

8.5 Flow Cell Cleaning

Explains post-separation flush and quick cleaning procedures for the flow cell.

8.6 PurIon Maintenance

Covers maintenance for PurIon systems, including probe removal and cleaning.

8.8 Electrical Troubleshooting

Guides checking line cord and fuses for electrical issues and touch panel display problems.

Table 8-2 Common PurIon Error Codes and Resolutions

Lists PurIon error codes and their corresponding solutions for troubleshooting.

Table 8-3 General Troubleshooting

Lists general troubleshooting steps for common system errors.

Certificate of Compliance

DECLARATION OF CONFORMITY

CombiFlash Hazmat Table

Teledyne Isco One Year Limited Warranty*

Related product manuals