CONFIG Commands
<start_time> - Unix time* - optional. If it is
ommited, <start_time> equals device startup time
* - there will be added also the HH:MM format
option (under development)
Response
OK<CR><LF>
Response example
As above
CONFIG GET PERIODIC
REBOOT<CR><LF>
Returns periodic restart time and start time in
hours
Response
x xxxxxxxxxx<CR><LF>*
* - there will be added also x xx:xx format option
(under development)
Response example
1 1619515560<CR><LF>*
Where:
1 is <time>
1619515560 is <start_time>
* - there will be added also 1 10:30 format option
(under development)
CONFIG SET UART
<configuration><CR><LF>
Configures UART
Where:
<configuration> - configuration string in the
format xxxx abc where xxxx = baudrate, a = start
bits, b = parity, c = stop bits
Response
OK<CR><LF>
Response example
As above
CONFIG GET UART<CR><LF>
Returns UART configuration
Response
xxxx xxx<CR><LF>
Response example
9600 8N1<CR><LF>
Where:
9600 is baudrate