HE863 family AT commands reference guide
80377ST10083a Rev.6 – 2012-11-12
Reproduction forbidden without written authorization from Telit Communications S.p.A.- All Rights Reserved. Page 105 of
229
3.5.3.8. Commands For Battery Charger
3.5.3.8.1. Battery Charge - +CBC
+ CBC - Battery Charge
AT+CBC
Execution command returns the current Battery Charge status in the format:
+CBC: <bcs>,<bcl>
where:
<bcs> - battery status
0 - ME is powered by the battery
<bcl> - battery charge level(0 ~ 100)
Note: <bcl> indicates battery charge level only if battery is connected and charger
is not connected.
AT+CBC=?
Test command returns parameter values supported as a compound value.
+CBC: (0),(0-100)
Note: although +CBC is an execution command, 3gpp TS 27.007 requires the Test
command to be defined.
Example
AT+CBC
+CBC: 0,75
OK
Note The ME does not make differences between being powered by a battery or by a
power supply on the VBATT pins, so it is not possible to distinguish between these
two cases.
Reference 3GPP TS 27.007

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions HE863 Series and is the answer not in the manual?

Telit Wireless Solutions HE863 Series Specifications

General IconGeneral
BrandTelit Wireless Solutions
ModelHE863 Series
CategoryControl Unit
LanguageEnglish

Related product manuals