HE863 family AT commands reference guide
80377ST10083a Rev.6 – 2012-11-12
Reproduction forbidden without written authorization from Telit Communications S.p.A.- All Rights Reserved. Page 30 of 229
3.5.2. Hayes Compliant AT Commands
3.5.2.1. Generic Modem Control
3.5.2.1.1. Set To Factory-Defined Configuration - &F
&F - Set To Factory-Defined Configuration
AT&F[<value>]
Execution command sets the configuration parameters to default values specified by
manufacturer; it takes in consideration hardware configuration switches and other
manufacturer-defined criteria.
Parameter:
<value>:
0 - just the factory profile base section parameters are considered.
1 - either the factory profile base section and the extended section are considered
(full factory profile).
Note: if parameter <value> is omitted, the command has the same behaviour as
AT&F0
Reference V25ter.
3.5.2.1.2. Soft Reset - Z
Z - Soft Reset
ATZ[<n>]
Execution command loads the default factory profile.
Parameter:
<n>
0..1 - user profile number ( No effect on behaviour )
Note: any call in progress will be terminated.
Note: if parameter <n> is omitted, the command has the same behaviour as ATZ0.
Reference V25ter.
3.5.2.1.3. Select Active Service Class - +FCLASS
+FCLASS - Select Active Service Class
AT+FCLASS=<n>
Set command sets the wireless module in specified connection mode (data, voice),
hence all the calls done afterwards will be data or voice.
Parameter:
<n>
0 - data

Related product manuals