#SHDN - Software Shutdown
AT#SHDN
Execution command causes device detach from the network and shut down.
Before definitive shut down an OK response is returned.
Note: after the issuing of this command any previous activity is terminated and the
device will not respond to any further command.
Note: to turn it on again Hardware pin ON/OFF must be tied low.
Note: to turn it off, USB_VBUS pin must be tied low.
Note: The maximum time to completely shutdown the device is 25 seconds.
AT#SHDN=?
Test command returns the OK result code.
3.5.5.1.8. Query Temperature Overflow - #QTEMP
#QTEMP - Query Temperature Overflow
AT#QTEMP=<mode
>
Set command has currently no effect. The interpretation of parameter
<mode> is currently not implemented: any value assigned to it will simply have no
effect.
Response format
AT#QTEMP?
Read command queries the device internal temperature sensor for over temperature
and reports the result in the format:
#QTEMP: <temp>
where:
<temp> - over temperature indicator
0 - the device temperature is in the working range
1 - the device temperature is out of the working range
Note: typical temperature working range is (-10°C..+55°C); anyway you are
strongly recommended to consult the “Hardware User Guide” to verify the
real temperature working range of your module
#QTEMP=?
Test command reports supported range of values for parameter <mode>.
Note The device should not be operated out of its working temperature range, elsewhere
proper functioning of the device is not ensured.
3.5.5.1.9. Temperature Monitor - #TEMPMON
#TEMPMON - Temperature Monitor
AT#TEMPMON=
<mod>
[,<urcmode>
[,<action>
[,<hyst_time>
Set command sets the behaviour of the module internal temperature monitor.
Parameters:
<mod>
0 - sets the command parameters.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions HE863 Series and is the answer not in the manual?

Telit Wireless Solutions HE863 Series Specifications

General IconGeneral
BrandTelit Wireless Solutions
ModelHE863 Series
CategoryControl Unit
LanguageEnglish

Related product manuals