HE863 family AT commands reference guide
80377ST10083a Rev.6 – 2012-11-12
Reproduction forbidden without written authorization from Telit Communications S.p.A.- All Rights Reserved. Page 139 of
229
010, 011, 100, 101, 110 and 111)
<hyst_time> - hysteresis time: all the actions happen only if the extreme or
operating bounds are maintained at least for this period. This
parameter is needed and required if <action> is not zero.
0..255 - time in seconds
Note: <action> can assume values from 1-7
<GPIO> - GPIO number. Valid range is “any output pin” (see “Hardware
User’s Guide”). This parameter is needed and required only if
<action>=4 is enabled.
Note: if the <GPIO> is specified <action> shall assume values from 4-7.
Note: last <urcmode> settings are saved as extended profile parameters.
Note: last <action>, <hyst_time> and <GPIO> settings are global
parameters saved in NVM
AT#TEMPMON?
Read command reports the current parameter settings for #TEMPMON
command in the format:
#TEMPMON: <urcmode>,<action>[,<hyst_time>[,<GPIO>]]
AT#TEMPMON=?
Test command reports the supported range of values for parameters <mod>,
<urcmode>, <action>, <hyst_time> and <GPIO>
Note In the following table typical temperature bounds are represented;
anyway you are strongly recommended to consult the “Hardware
User Guide” to verify the real temperature bounds for your module.
Extreme Temperature Lower Bound
(*)
T
ext_low
Operating Temperature Lower Bound
(*)
T
op_low
Operating Temperature
Operating Temperature Upper Bound
(*)
T
op_up
Extreme Temperature Upper Bound
(*)
T
ext_up
(*)
Due to temperature measurement uncertainty there is a tolerance of
+/-2°C
3.5.5.1.10. General Purpose Input/Output Pin Control - #GPIO