HE863 family AT commands reference guide
80377ST10083a Rev.6 – 2012-11-12
Reproduction forbidden without written authorization from Telit Communications S.p.A.- All Rights Reserved. Page 14 of 229
commands in the same command line, because if one of them fails, then an error message is
received but it is not possible to argue which one of them has failed the execution.
If command V1 is enabled (verbose responses codes) and all commands in a command line
has been performed successfully, result code <CR><LF>OK<CR><LF> is sent from the TA
to the TE, if subparameter values of a command are not accepted by the TA or command
itself is invalid, or command cannot be performed for some reason, result code
<CR><LF>ERROR<CR><LF> is sent and no subsequent commands in the command line
are processed.
If command V0 is enabled (numeric responses codes), and all commands in a command line
has been performed successfully, result code 0<CR> is sent from the TA to the TE, if sub-
parameter values of a command are not accepted by the TA or command itself is invalid, or
command cannot be performed for some reason, result code 4<CR> and no subsequent
commands in the command line are processed.
In case of errors depending on ME operation, ERROR (or 4) response may be replaced by
+CME ERROR: <err> or +CMS ERROR: <err>.
NOTE: The command line buffer accepts a maximum of 80 characters. If this number is
exceeded none of the commands will be executed and TA returns ERROR.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions HE863 Series and is the answer not in the manual?

Telit Wireless Solutions HE863 Series Specifications

General IconGeneral
BrandTelit Wireless Solutions
ModelHE863 Series
CategoryControl Unit
LanguageEnglish

Related product manuals