Telit Wireless Solutions ME910C1-WW - Packaging Detail; Moisture Sensitivity

Telit Wireless Solutions ME910C1-WW
99 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ME910C1 HW User Guide
1VV0301351 Rev.8 Page 91 of 99 2018-09-28
Packaging detail
Moisture sensitivity
The ME910C1 is a Moisture Sensitive Device level 3, in according with standard
IPC/JEDEC J-STD-020, take care all the relatives requirements for using this kind of
components.
Moreover, the customer has to take care of the following conditions:
a) Calculated shelf life in sealed bag: 12 months at <40°C and <90% relative humidity
(RH).
b) Environmental condition during the production: 30°C / 60% RH according to
IPC/JEDEC J-STD-033A paragraph 5.
c) The maximum time between the opening of the sealed bag and the reflow process must
be 168 hours if condition b) “IPC/JEDEC J-STD-033A paragraph 5.2” is respected
d) Baking is required if conditions b) or c) are not respected
e) Baking is required if the humidity indicator inside the bag indicates 10% RH
or more

Table of Contents

Other manuals for Telit Wireless Solutions ME910C1-WW

Related product manuals