STEPS COMMON TO ALL LOW VOLTAGE INSTALLATION METHODS
33. Hook the thermostat to the hinges on the top of the backplate.
34. Line up the hinges on the thermostat to the notches on the backplate. Press the
top of the thermostat tightly against the back plate.
35. Slowly bring the top down as shown. Use care not to force the faceplate closed.
If you encounter resistance, make sure no wires are pinched between com-
ponents and that no pins are bent.
36. Once the thermostat has been snapped onto the back plate, use a Phillips head
screw driver to insert the safety screw.
37. Remove all lockouts or tags from the circuit breaker.
38. Return the electrical circuit to operation.
39. Test all components to make sure that you can engage both the heat and air
conditioning, and all supported fan settings (high, low, etc.). Wiring is complete.