CARRIER EN
PA VOLTAGE
PA CURRENT
MAX PW SET
RFL PW SET
4.6.5
A07A2200S
shows if the output power is enabled either by a keyboard command
or by an external command through the IN/OUT rear connector.
is the supply voltage of the RF power final mosfet.
is the voltage drained by the mosfet final power.
is the maximum power value which can be programmed by the
keyboard in the screen shot Forward PW adj (10–2100W) to avoid
accidental over setting.
is the maximum allowed output reflected power. Should this limit be
reached, the direct power will be reduced to keep constant the limit
value of the reflected power
By entering again PAGE UP, eventual alarms present in the memory
will be displayed:
They are stored in a chronological order ordered by number, type and date.
Besides the real alarm, also the complementary event is stored (return to normality), in order to
know the alarm period time:
By entering PAGE UP, the next alarm is displayed, or, if in the last screen shot of main measures
there was not any alarm, it will be displayed the screen shot for the PASSWORD request to access
the measures. If inside the transmitter the Z2 jumper placed on the DLCD board (in the rear of the
front display panel board) is placed to OFF, this request is skipped, so it’s possible to directly set
the transmitter.