PLEASE READ THIS MANUAL
BEFORE INSTALLING AND
USING HEATERS
IMPORTANT: Read all instruc-
tions and warnings carefully
before starting installation. Fail-
ure to follow these instructions
may result in a possible fire haz-
ard and will void the warranty.
WARNING: If the information in
this manual is not followed ex-
actly, a fire or explosion may
result causing property damage,
personal injury or loss of life.
— Do not store or use gasoline or
other flammable vapors and
liquids in the vicinity of this or
any other appliance.
— What to Do If You Smell Gas
Do not try to light any appli-
ance.
Do not touch any electrical
switch; do not use any phone
in your building.
Immediately call your gas
supplier from a neighbor's
phone. Follow the gas
supplier's instructions.
If you cannot reach your gas
supplier, call the fire depart-
ment.
— Installation and service must be
performed by a qualified in-
staller, service agency or the
gas supplier.
This is an unvented gas-fired
heater. It uses air (oxygen) from
the room in which it is installed.
Provisions for adequate combus-
tion and ventilation air must be
provided. Refer to Page 4.
Vent-Free Gas Fireplaces
Models:
VF36RN, VF36RNH, VF36RP
Homeowners Installation and
Operating Instructions
5L24
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777
Temco Fireplace Products
Gas Fired
Unvented
Room Heaters
INSTALLER: DO NOT DISCARD THIS MANUAL - Leave in fireplace for homeowner.
Models with “N” after the model number use natural gas;
models with “P” after the model number use Propane
(LP) gas.
78586 11/03 Rev. 8
This appliance is UL Certified under ANSI Standard
Z21.11.2-2000 as an unvented room heater

Questions and Answers

  • N
    Natalie StarkAug 10, 2025
    Why won't the pilot light on my Temco VF36RN?
    • T
      Tanya White DDSAug 10, 2025
      Several factors can prevent the pilot light from igniting on your Temco Indoor Fireplace. It could be due to air in the gas line, which requires purging the lines and repeating the ignition process. Alternatively, there might be low gas pressure, a turned-off gas supply, or a blockage in the gas line, each needing to be checked and corrected. The control knob may not be in the pilot position or may not be pressed in while in pilot position. In case the ODS pilot orifice is clogged, it's best to call a qualified service person.
  • A
    aknoxAug 15, 2025
    What to do if the pilot light won't stay lit on my Temco VF36RN Indoor Fireplace?
    • M
      Michael StrongAug 15, 2025
      If the pilot light on your Temco Indoor Fireplace won't stay lit, several issues could be the cause. The ODS pilot orifice might be partially clogged, in which case you should contact a qualified service person or your gas company. There could be corrosion on the thermocouple contact, which needs cleaning. Other potential causes include a bad gas valve (which would need replacing), the control knob not being pressed in long enough (ensure you hold it for 60 seconds after lighting), a loose or damaged thermocouple connection (tighten or replace as needed), or the pilot flame not touching the thermocouple (requires a qualified service person).
  • C
    Colton HowellAug 19, 2025
    How to fix a Temco Indoor Fireplace when the main burner will not light?
    • J
      Jose ChurchAug 20, 2025
      If the main burner on your Temco Indoor Fireplace isn't lighting, start by checking the gas supply pressure; if it's low, contact your gas supplier. Also, inspect the burner orifice for any clogs and clean it if necessary. Finally, ensure that the control knob is turned to the 'ON' position.
  • D
    Dennis SnyderAug 25, 2025
    What to do if the ignitor doesn't spark on my Temco VF36RN Indoor Fireplace?
    • J
      jamesolsonAug 25, 2025
      If the ignitor on your Temco Indoor Fireplace isn't sparking, it could be due to several reasons. The ignitor electrode might be positioned incorrectly, or the electrode itself could be broken, requiring replacement of the assembly. Check the ignitor cable for any pinching or breaks; free it if pinched, and replace it if damaged. Also, ensure the ignitor cable is properly connected to the ignitor.
  • L
    littlepatrickAug 30, 2025
    Why does my Temco Indoor Fireplace heater shut off on ODS?
    • R
      rfoleyAug 30, 2025
      If your Temco Indoor Fireplace heater shuts off on the ODS (Oxygen Depletion Sensor), it could be due to a few reasons. Make sure that enough fresh air is available by opening a window. Alternatively, there might be low gas pressure, in which case you should contact your gas supplier. It's also possible that the ODS pilot is only partially lit, which requires a qualified service person.
  • T
    Tyler KelleySep 4, 2025
    How to stop my Temco VF36RN from sooting?
    • M
      Meghan JenningsSep 4, 2025
      Sooting in your Temco Indoor Fireplace can occur due to several factors. Low gas pressure could be the cause, so contact your gas company. A clogged air intake or orifice can also lead to sooting, requiring cleaning by a service agent. Flame impingement, often caused by air currents around the appliance, can also be a culprit - ensure there are no drafts. Lastly, misplaced logs can cause sooting, so refer to the installation instructions for proper log placement.

Temco VF36RN Specifications

General IconGeneral
Model NumberVF36RN
Fuel TypeNatural Gas or Liquid Propane
Log MaterialCeramic Fiber
Burner MaterialStainless Steel
FinishBlack
WarrantyLimited Lifetime
Product TypeFireplace