Port Management
- 20 -
Demand: the monitoring of the messages received and sent by division 1 and division 2 is
expected to be implemented through the server.
Networking Analyses
Specified as follows, the demand is realized by making use of the port mirroring.
Port 1 and port 2 are selected to be the source ports of mirroring with “receiving and
sending direction of mirroring”.
Port 3 connected with the server is set as the mirroring destination port.
Networking Diagram
Configuration procedures
1. Log in the Web administration page of the switch C, then click Port Management > Port
Mirroring to enter the setting page
2. The Mirroring Destination Port: select “3”.
3. The Mirroring Status: Check the source port 1 and 2;
4. The Sniffer Mode: Select “Egress & Ingress”.
5. Click OK