69
General Specifications
z Maximum Voltage between any Terminals and grounding: Refer to the different range input
protection voltage.
z
Fuse Protection of ȝA mA terminal: 1A, H 240V, fast type, ij6x25mm
z
Fuse Protection of A terminal: 10A,H 240V, fast type, ij6x25mm
z Maximum Display: 4000; analogue bar graph 41 segments
z Measurement Speed: Updates 2-3 times/second
z Range: Auto or manual
z Polarity Display˗Auto
z Overload Display: OL
z Battery Deficiency: Display
.
z Temperature:
Operating: 0°C ~40°C (32°F~104°F).
Storage: -10°C ~50°C (14°F ~122°F).
z Relative Humidity : d75% @ 0°C to 30°C;
d 50% @ 30°C to 40°C.
z Altitude: Operating : 2000m; Storage: 10000m.
z Electromagnetic Compatibility: EN61326-1:2006, EN61326-2:2006
z Battery Type: 9V (NEDA1604 or 6F22 or 006P).
z Dimensions (HxWxL): 180 x 87 x 47mm
z Weight: 370g (including holster and battery)
z Safety/Compliances:
72-9280: OPERATING MANUAL