TM-12E/13E/13R
EN-7
Frequency (Auto-Ranging)(12E)
Range
Resolution
Accuracy
Max.
Sensitivity
Overload
Protection
4KHz
1Hz
(0.8%+3)
3V rms
DC/AC
600V rms
40KHz
10Hz
400KHz
100Hz
Continuity
Range
Buzzer
Max. Open Voltage
Overload
Protection
below 40
About-1.5VDC
600V rms
Resistance (12E)
Range
Resolution
Accuracy
Max. Open
Voltage
Overload
Protection
(400)
0.1
(1%+5)
About-1.5V
DC
600V rms
Resistance (Auto/Manual)(13E/13R)
Range
Resolution
Accuracy
Max.
Sensitivity
Overload
Protection
400
0.1
(1%+5)
about -1.5V
DC
DC/AC
600V rms
(60 Second)
4K
1
(1%+3)
About-0.45V
DC
40K
10
400K
100
4M
1K
40M
10
(3%+3)