2-3
2.4 Nameplate entries
The specifications of the pump are shown on the nameplate. When you receive the pump, check the
nameplate to verify that the product is exactly what you ordered. Be sure to confirm the model,
motor output, frequency and voltage.
If any part of the product should be different from what you ordered, contact the vendor from which
you purchased the product.
Keep the nameplate easy to check without placing an obstacle in front of it or removing it.
Caution
Do not allow the pump to operate with a frequency beyond 60 Hz.
Doing so may overload the motor, causing it to burn out.
2.5 Specification table
• Standard leg
Type
Specifications
VKD111AA-e VKD131AB-e VKD141AC-e VKD151AD-e
Output (kW) 0.75 1.5 2.2 3.0
Rated voltage (V) 200
200
220
200
200
220
200
200
220
200
200
220
Frequency (Hz) 50 60 50 60 50 60 50 60
5.0 9.1 12.1 16.2
Rated current (A) 4.7
4.9
7.6
7.9
12.0
10.7
14.5
14.6
32.5 45.5 72.0 115
Starting current (A) 34.0
36.0
49.0
50.0
78.0
79.0
120
126
Discharge rate (L/min) 80 to 300 100 to 400 80 to 400 100 to 500 80 to 400 100 to 500 80 to 400 100 to 500
Total head (m) 8 to 4 12 to 4 20 to 7 28 to 7 29 to 9 40 to 9 40 to 14 54 to 14
Applicable limit value of
dynamic viscosity (mm
2
/s)
75 75 75 75 75 75 75 75
Note 1) The discharge quantity / total head is indicated with the value when tested at a dynamic viscosity of 1 mm
2
/
s
(equivalent to normal-temperature
fresh water). Notice that the pump cannot be used with water.
Note 2) The rated current in the above table (current value stated on the pump nameplate) is the recommended preset current value of the protective
device.
• Long leg
4Type
Specifications
VKD131AF-e VKD141AG-e VKD151AH-e
Output (kW) 1.5 2.2 3.0
Rated voltage (V) 200
200
220
200
200
220
200
200
220
Frequency (Hz) 50 60 50 60 50 60
9.1 12.1 16.2
Rated current (A) 7.6
7.9
12.0
10.7
14.5
14.6
45.5 72.0 115
Starting current (A) 49.0
50.0
78.0
79.0
120
126
Discharge rate (L/min) 80 to 400 100 to 500 80 to 400 100 to 500 80 to 400 100 to 500
Total head (m) 18 to 4 25 to 2 27 to 7 38 to 7 37 to 11 50 to 8
Applicable limit value of
dynamic viscosity (mm
2
/s)
75 75 75 75 75 75
Note 1) The discharge quantity / total head is indicated with the value when tested at a dynamic viscosity of 1 mm
2
/
s
(equivalent to normal-temperature
fresh water). Notice that the pump cannot be used with water.
Note 2) The rated current in the above table (current value stated on the pump nameplate) is the recommended preset current value of the protective
device.
Symbol Item
1 Type
2 Motor output (kW)
3 Nominal discharge diameter (B)
4 Total head (m)
5 Discharge rate (L/min)
6 Frequency (Hz)
7 Voltage (V)
8 Current (A)
9 Rotating speed (min
-1
)
10 Max. permissible rotating speed (min
-1
)
11 Year of manufacture
12 Instruction manual No.
13 Inboard bearing type
14 Outboard bearing type
15 Production No.
Pump nameplate