1. Wiring diagram
NOTE:
Must be hard wired, no plug allowed (In Australia,
For your safe use in winter, it’s strongly
For the detailed wiring diagram, please refer to Appendix 1.
2
. Options for protecting devices and cable specification
MODEL
AIC06 AIC08
Breaker
Rated
A
9.0 9.0
Residual
Action Current
mA
30 30
Fuse A
9.0 9.0
Power Cord
(
mm
2
)
3×1.5 3×1.5
Signal cable
(
mm
2
)
3×0.5 3×0.5
NOTE: The above data is adapted to power cord ≤ 10m.
be increased. The signal cable can be extended to 50m at most.
文件中找不到关系 ID
为 rId104 的图像部
件。
文件中找不到关系 ID
为 rId105 的图像部
件。
A. For power
Distribution Box(Customer prepare)
Power Supply
400V 50Hz
Breaker
Distribution Box(Customer prepare)
Power Supply
230V 50Hz
Breaker
B. For power supply: 400V 50Hz
Earthing
Earthing
12
Must be hard wired, no plug allowed (In Australia,
AIC08~ AIC
13 has plug for optional).
For your safe use in winter, it’s strongly
recommended to equip heating priority function.
For the detailed wiring diagram, please refer to Appendix 1.
. Options for protecting devices and cable specification
AIC10 AIC12 AIC13 AIC17 AIC21
10.5 13.0 13.5 16.0 21.0
30 30 30 30 30
10.5 13.0 13.5 16.0 21.0
3×2.5 3×2.5 3×2.5 3×2.5 3×4
3×0.5 3×0.5 3×0.5 3×0.5 3×0.5
NOTE: The above data is adapted to power cord ≤ 10m.
If power cord is
>
be increased. The signal cable can be extended to 50m at most.
Distribution Box(Customer prepare)
Power Cord
Swimming Pool Heat Pump Wiring Board
Distribution Box(Customer prepare)
Power Cord
Swimming Pool Heat Pump Wiring Board
B. For power supply: 400V 50Hz
Fuse
Fuse
13 has plug for optional).
recommended to equip heating priority function.
AIC28 AIC28T AIC35T
24.0 9.0 12.0
30 30 30
24.0 9.0 12.0
3×6 5x2.5 5x2.5
3×0.5 3×0.5 3×0.5
Swimming Pool Heat Pump Wiring Board
Swimming Pool Heat Pump Wiring Board