0
1
t
d(BOR)
V
CC
V
(B_IT−)
V
hys(B_IT−)
V
CC(start)
MSP430F23x
MSP430F24x(1)
MSP430F2410
SLAS547I JUNE 2007REVISED DECEMBER 2012
www.ti.com
POR and Brownout Reset (BOR)
(1)(2)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS V
CC
MIN TYP MAX UNIT
V
CC(start)
Operating voltage dV
CC
/dt 3 V/s 0.7 × V
(B_IT-)
V
V
(B_IT-)
Negative going V
CC
reset threshold voltage dV
CC
/dt 3 V/s 1.71 V
V
hys(B_IT-)
V
CC
reset threshold hysteresis dV
CC
/dt 3 V/s 70 130 210 mV
t
d(BOR)
BOR reset release delay time 2000 µs
Pulse duration needed at RST/NMI pin to
t
(reset)
2.2 V, 3 V 2 µs
accepted reset internally
(1) The current consumption of the brownout module is already included in the I
CC
current consumption data.
The voltage level V
(B_IT-)
+ V
hys(B_IT-)
is 1.8 V.
(2) During power up, the CPU begins code execution following a period of t
d(BOR)
after V
CC
= V
(B_IT-)
+ V
hys(B_IT-)
. The default DCO settings
must not be changed until V
CC
V
CC(min)
, where V
CC(min)
is the minimum supply voltage for the desired operating frequency.
Figure 9. POR/Brownout Reset (BOR) vs Supply Voltage
38 Submit Documentation Feedback Copyright © 2007–2012, Texas Instruments Incorporated