Premier 640 Quick Reference Guide Factory Defaults
INS296 3
Menu Option Default
3. Global Options
Config Options 23: User Code Latch Pulse
Continued 24: Test Call = CT4 Timed
25: Batt Test = Disarm Timed
26: Bell = 2nd Alarm 1st Alarm
27: SNDR = 2nd Alarm 1st Alarm
28: Conf. = Delayed Instant
29: Abort = User Reset Eng.
30: Manual AV Output Auto
31: Clock = Crystal 50Hz
32: 40 Column Print 80
33: Enable Text Disable
34: EN50131 Disabled Enabled
35: 1st Zone=Confirm 2nd
36: Keypads Local Global
37: Panel Grade 2 3 *
38: Enable RF FOB PA Disable
39: Armed Mask=Alarm Fault
System Options 1: Advisory Volume 5
2: Chime Volume 3
3: No. of Re-Arms 03
4: Anti-code Resets 03
5: Multi Knocks 05
6: Clock Adjustment 50 (no
adjustment)
7: Quick Count 4
8: Modem Level 0
Monitor Hardware 1: ATS Path Faults Enabled
2: Power Failure Enabled
3: Aux Fuse Blown Enabled
4: Bell Tamper Enabled
5: Aux Tamper Enabled
6: Panel Lid Tamper Enabled
7: Battery Faults Enabled
Control Timers 1 – 8 Not Defined
System Text Reset Message Call Engineer to
Reset System
Anti-code Message Call ARC Centre
to Reset System
Service Message Call Alarm Co.
For Service
Location Text No Location Text
Has Been Setup
Banner Message Not Defined
Part Armed Banner Not Defined
Printer Header Not Defined
Part Arm Text Part Arm 1 Evening Arm
Part Arm 2 Bedtime Arm 1
Part Arm 3 Bedtime Arm 2
Holiday Dates 1 - 8 Not Defined
Speaker Tones All Tones Enabled
PC Output Text All Tones Not Defined
Custom O/P Text All Tones Not Defined
4. Keypad Setup
Areas All Keypads Area A
Zone Mapping All Keypad zones Not Mapped
Options 1: PA Enabled Disabled
2: Fire Enable Disabled
3: Medical Enabled Disabled
4: Tamper Disabled Enabled
5: PA Silent Audible
6: PA Delayed Instant
7: Quick Arm Keys Off
8: Info.LED> Output Armed
Volume All Keypads 4
Sounder Options All Tones Enabled
Menu Option Default
5. Expander Setup
Areas All Expanders Area A
Text All Expanders Not Defined
Auxiliary Input All Expanders Not Used
Volume All Expanders 4
Sounder Options All Tones Enabled
6. Output Setup
Panel Outputs 1 - 5 Not Used
Digi Outputs 1 Tamper ***
2 AC Mains Fail
***
3 ATS Test ***
4 Not Used ***
5 Not Used ***
6 LED Control ***
7 Armed ***
8 Detector Test ***
Com Channels 1 Fire
2 PA
3 Alarm
4 Armed
5 Zones Locked
Out
6 Fault Present
7 Confirmed Alarm
8 Abort
RedCARE Pins 1 Fire
2 PA
3 Intruder Alarm
4 Armed
5 Zones Locked
Out
6 Fault Present
7 Confirmed Alarm
8 Abort
Keypads 1-8 Outputs LED Control LED Control
Expanders 1-8 Outputs 1 LED Control
2 Armed
3 Detector Test
4 - 8 Not Used
5 Entry
6 Not Used
7 - 8 Always ON
Custom O/P 1 1 Control Timer 1
2 Not Used
3 - 4 Always ON
5 - 8 Not Used
Custom O/P 2 1 Control Timer 3
2 Not Used
3 - 4 Always ON
5 Entry
6 Not Used
7 - 8 Always ON
Custom O/P 3 1 - 8 Not Used
Custom O/P 4 1 - 8 Not Used
X-10 Outputs 1 - 8 Not Used
7. UDL/Digi Options
Reset Digi N/A N/A
Test Com? N/A N/A
Set Call Waiting Number Not Defined
Program Digi ARC 1 Not Defined
ARC 2 Not Defined
ARC 3 Not Defined
Digi Options Digi is Enabled Disabled
Pulse Dialling Tone
Pulse After 3 Always Tone
Blind Dialling Wait Dial Tone
Call Waiting On Off
Dial All Numbers Dial Any