Three Phase
Openwell
Submersible
Monoblocks
Instruction &
Operating Manual
OMOW001A 2020.01

Questions and Answers

  • M
    millerjoshuaAug 3, 2025
    Why Texmo Industries Water Pump does not run?
    • J
      James WebbAug 3, 2025
      There are several reasons why your Texmo Industries Water Pump might not be running. It could be due to: * No power supply: Check if power is available. * Burnt motor coil: The motor may need rewinding. * Low voltage: Ensure operation within the recommended voltage range. * Tripped motor starter overload: Reset the overload, but if it trips again, check the voltage. * Pump jammed: Dismantle the pump to clear any jammed parts. * Blown fuse: Replace the fuse. * Loose connections: Tighten all electrical connections. * Prolonged idleness: Run the pump for a few minutes every other day to ensure free shaft rotation.
  • E
    elizabethcummingsAug 13, 2025
    Why Texmo Industries Water Pump current consumption is in excess?
    • J
      John RobertsAug 13, 2025
      Excessive current consumption in your Texmo Industries Water Pump can stem from several issues: * Damaged thrust bearing: Replace the worn-out bearing. * Low voltage: Check the voltage supply. * Defective rotor: Replace the rotor. * Excessive wear: Service the pump, replacing worn parts. * Low system head: Throttle the discharge.
  • J
    Jonathan HallAug 18, 2025
    Why is the total head developed by my Texmo Industries Water Pump too low?
    • L
      Lindsey ThorntonAug 18, 2025
      If your Texmo Industries Water Pump isn't developing enough head, here are a few possible reasons: * Abrasive wear: If the pump operates with water that has a high sand content or is corrosive, it can cause abrasive wear of pump hydraulics. You should change the worn-out pump parts. * Change in static head: Check the actual static head. * Low voltage: Wait for the voltage to increase.
  • R
    Robert ReyesAug 23, 2025
    How to fix a Texmo Industries Water Pump that runs rough and noisy?
    • P
      Paul FowlerAug 23, 2025
      A Texmo Industries Water Pump that runs roughly and noisily might have these problems: * Dry running: Keep the pump idle for some time or reduce the discharge by throttling. * Bent shaft: Replace the shaft. * Excessive wear: Service the pump, replacing the worn-out parts.
  • D
    Douglas StantonAug 28, 2025
    What to do if Texmo Industries Water Pump leaks excessively?
    • J
      Jerry KnappAug 28, 2025
      If your Texmo Industries Water Pump is leaking excessively, the cause may be: * Damaged gaskets/O-rings: Check and replace the gaskets or O-rings. * Damaged pipeline: Check and replace the piping.
  • J
    Julie MayNov 7, 2025
    What to do if Texmo Industries Water Pump has less discharge?
    • C
      Carol BassNov 7, 2025
      If your Texmo Industries Water Pump is discharging less water than expected, consider these potential causes and solutions: * Low voltage: Check the supply voltage and ensure it's within the recommended range. * Incorrect rotation direction: Interchange the supply connections of any two phases. * Excessive delivery head: Make sure the delivery head is within the specified value. * Undersized pipe: Replace the pipe with the size recommended on the nameplate. * Internal pipe deposits: Clean the discharge pipe. * Foreign objects in impellers: Inspect and remove any foreign bodies lodged in the impellers. * Partially closed/blocked valve: Check, clean, or replace the valves in the discharge pipe. * Blocked check valve: Inspect, clean, and replace the pump's check valve if nece...

Summary

Introduction

Warranty Information

Complying with Standards

Contents of the Packing Box

Information About Your Pump

Schematic Drawing

Key Specifications & Features

Cross-Section View

Pre-installation Requirements

Installation Procedure

Cable Lead Wire Connection to Starter

Details for connecting power cables to starter terminals for DOL and Star-Delta configurations.

Cable Selection Guide

Chart for selecting appropriate cable sizes based on motor rating, current, and length.

Checking Direction of Rotation

Procedure to verify correct impeller rotation by testing phase wire connections.

Electrical Installation Guidelines

Guidelines for electrical setup, including connection procedures and safety precautions.

Basic Troubleshooting

Preventive Maintenance Checks

Dos and Donts

Important Safety Instructions

Storage & Handling

Company Contact Information

Texmo Industries TARO TSM Series Specifications

General IconGeneral
TypeSubmersible Pump
PhaseSingle Phase
Pump Body MaterialCast Iron
Frequency50 Hz
ShaftStainless Steel
ApplicationDomestic, Agricultural, Industrial
Motor Power0.5 HP to 2 HP
Voltage220V
Impeller MaterialCast Iron