After the Secondary server has communicated with Primary Server
successfully, then the state will changed to:
Click Yes to reboot both Primary and Secondary server.
If the communication has failed then you will see an error message as below.
Conditions in which the secondary server will take over to play the role as
Active:
1. Primary server RAID is damaged
2. Loss of the primary server’s data port connection
3. Primary server goes down for any other reason
When the primary server encounters the above-mentioned situations, the
secondary server (PMS) will immediately take over to play the role as active. The
secondary server's system log will show "HA changed to active, getting resources",
and "Healthy: The RAID [HA] on system [PMS] is healthy now."

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thecus N5550 and is the answer not in the manual?

Thecus N5550 Specifications

General IconGeneral
RAID levels0, 1, 5, 6, 10, JBOD
Hot-swap drive baysYes
Storage drive capacity0 GB
Supported file systemsext3, ext4, XFS
Storage drive interfaceSerial ATA
Total installed storage capacity0 TB
Number of storage drives installed0
Number of storage drives supported5
Internal memory2 GB
Internal memory typeDDR3
Processor familyIntel Atom®
Number of processors installed1
Wi-FiNo
Data link protocolsTCP/IP/AppleTalk
Ethernet LAN data rates10, 100, 1000 Mbit/s
Maximum data transfer rate1000 Mbit/s
Supported network protocolsSMB/CIFS, HTTP/HTTPS, FTP, NFS v4, AFP
I/O ports1 x mic in 1 x line in 1 x audio out
Networking featuresGigabit Ethernet
Compatible operating systemsWindows 2000/XP/2003/Vista/ 7 UNIX/Linux Mac OS X
Security algorithms256-bit AES
Cables includedAC
FireWire 400FireWire-interface with a data transmission speed of 400 Mbit/s (50MB/s). FireWire is a serial computer bus technology designed as replacement of SCSI and is based on the IEEE 1394 and 1394b standards.
USB 2.0 ports quantity4
Ethernet LAN (RJ-45) ports2
Bundled softwareAcronis True Image Thecus Backup Utility
Display typeLCD
Product colorBlack
Power supply unit (PSU) capacity200 W
Operating temperature (T-T)5 - 40 °C
Operating relative humidity (H-H)0 - 80 %
Sustainability certificatesRoHS
CertificationCE/FCC/C-Tick/VCCI/BSMI VMware, Citrix, WEEE