Refrigeration Diagnosis
Rapid cycling between cool and heat
Unit cools in heat and defrost cycle
Unit heats in refrigeration cycle
High head pressure
Low head pressure
No head pressure
High suction pressure
Low suction pressure
No suction pressure
Unit operating in a vacuum
Receiver sight glass empty
Suction line frosting back
Unable to pump down system
Unable to pull vacuum in low side
Unable to hold vacuum in low side
Noisy compressor
Unit not refrigerating
Unit not heating or defrosting
SYMPTOM
POSSIBLE CAUSES
••
Overcharge of refrigerant
•• ••
Shortage of refrigerant
••
No refrigerant
Air through condenser too hot (ambient)
Air flow through condenser restricted
•••
Air through condenser too cold (ambient)
••
Air in refrigerant system
Condenser fan blades bent or broken
Air short cycling around evaporator coil
Air through evaporator restricted
•••
Evaporator needs defrosting
••
Compressor discharge valves leaking
••
Compressor suction valves leaking
Too much compressor oil in system
Faulty oil pump in compressor
Loose compressor pulley
Compressor bearing loose or burned out
••••
Broken valve plate in compressor
••
Expansion valve power element lost its charge
••
Expansion valve feeler bulb improperly mounted