Introduction
This manual is published for informational purposes only. Thermo King® makes no representations warranties express
or implied, with respect to the information recommendations and descriptions contained herein. Information provided
should not be regarded as all-inclusive or covering all contingencies. If further information is required, Thermo King
Corporation Service Department should be consulted.
TThheerrmmoo KKiinngg’’ss wwaarrrraannttyy sshhaallll nnoott aappppllyy ttoo aannyy eeqquuiippmmeenntt wwhhiicchh hhaass bbeeeenn ““ssoo iinnssttaalllleedd,, mmaaiinnttaaiinneedd,, rreeppaaiirreedd
oorr aalltteerreedd aass,, iinn tthhee mmaannuuffaaccttuurreerr’’ss jjuuddggmmeenntt,, ttoo aaffffeecctt iittss iinntteeggrriittyy..””
MMaannuuffaaccttuurreerr sshhaallll hhaavvee nnoo lliiaabbiilliittyy ttoo aannyy ppeerrssoonn oorr eennttiittyy ffoorr aannyy ppeerrssoonnaall iinnjjuurryy,, pprrooppeerrttyy ddaammaaggee oorr aannyy
ootthheerr ddiirreecctt,, iinnddiirreecctt,, ssppeecciiaall,, oorr ccoonnsseeqquueennttiiaall ddaammaaggeess wwhhaattssooeevveerr,, aarriissiinngg oouutt ooff tthhee uussee ooff tthhiiss mmaannuuaall oorr
aannyy iinnffoorrmmaattiioonn,, rreeccoommmmeennddaattiioonnss oorr ddeessccrriippttiioonnss ccoonnttaaiinneedd hheerreeiinn.. TThhee pprroocceedduurreess ddeessccrriibbeedd hheerreeiinn sshhoouulldd
oonnllyy bbee uunnddeerrttaakkeenn bbyy ssuuiittaabbllyy qquuaalliiffiieedd ppeerrssoonnnneell.. FFaaiilluurree ttoo iimmpplleemmeenntt tthheessee pprroocceedduurreess ccoorrrreeccttllyy mmaayy ccaauussee
ddaammaaggee ttoo tthhee TThheerrmmoo KKiinngg uunniitt oorr ootthheerr pprrooppeerrttyy oorr ppeerrssoonnaall iinnjjuurryy..
Software License
The product includes software that is licensed under a non-exclusive, non-sublicensable, terminable and limited license
to use the software as installed on the product for its intended purpose. Any removal, reproduction, reverse
engineering, or other unauthorized use of the software is strictly prohibited. Hacking the product or installing
unapproved software may void the warranty. The owner or operator shall not reverse engineer, decompile, or
disassemble the software, except and only to the extent that such activity is expressly permitted by applicable law
notwithstanding this limitation. The product may include third party software separately licensed as specified in any
documentation accompanying the product or in an about screen on a mobile application or website that interfaces with
the product.
Recover Refrigerant
NNoottee:: In the USA, EPA Section 609 Certification is required to work on motor vehicle air conditioning systems (MVAC).
At Thermo King®, we recognize the need to preserve the environment and limit the potential harm to the ozone layer
that can result from allowing refrigerant to escape into the atmosphere.
We strictly adhere to a policy that promotes the recovery and limits the loss of refrigerant into the atmosphere.
When working on transport temperature control systems, a recovery process that prevents or minimizes refrigerant
loss to the atmosphere is required by law. In addition, service personnel must be aware of the appropriate European
Union, National, Federal, State, and/or Local regulations governing the use of refrigerants and certification of
technicians. For additional information on regulations and technician programs, contact your local THERMO KING
dealer.
SSeerrvviiccee TToooollss - Use the proper service tools. Gauge manifold sets should include appropriate shutoff valves or
disconnects near the end of each service line.
RReeccoovveerryy EEqquuiippmmeenntt - Recovery equipment must be used. Proper recovering, storing and recycling of refrigerants is
an important part of all service work.
SSeerrvviiccee PPrroocceedduurreess - Recommended procedures must be used to minimize refrigerant loss.
CCoommppoonneennttss mmaayy bbee iissoollaatteedd by closing service valves and performing system pump-downs.
CCoommppoonneennttss uunnaabbllee ttoo bbee iissoollaatteedd for service must be repaired only after refrigerant is properly recovered.